中央孔位置对渐进性车头灯眩光源下有晶状体眼人工晶状体视觉功能的影响。

Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sources.

机构信息

Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain.

Instituto de Oftalmobiología Aplicada, Universidad de Valladolid, Valladolid, Spain; Red Temática de Investigación Colaborativa en Oftalmología, Instituto de Salud Carlos III, Madrid, Spain.

出版信息

J Cataract Refract Surg. 2019 Nov;45(11):1591-1596. doi: 10.1016/j.jcrs.2019.06.022.

Abstract

PURPOSE

To analyze the effect of the central hole location in the V4c implantable collamer lens (ICL) on the quality of vision, including progressive headlight glare simulation and quality of life.

SETTING

IOBA-Eye Institute, Valladolid, Spain.

DESIGN

Case series.

METHODS

The central hole location was determined by slitlamp and dual Scheimpflug imaging for 6 months or more postoperatively. The visual acuity, mesopic contrast sensitivity, halogen glare contrast sensitivity, xenon glare contrast sensitivity, photostress recovery time after glare, de Boer scale, and Quality of Life Impact of Refractive Correction (QIRC) questionnaire results were evaluated. Multiple regression models were used to analyze the effect of the central hole location on parameters using the pupil center and visual axis as references based on Cartesian and polar coordinates.

RESULTS

The safety index was 1.13 and the efficacy index, 1.12. Under all testing circumstances, central hole decentration did not affect the visual acuity or contrast sensitivity. With the visual axis as a reference, worse QIRC values were associated with greater upward central hole displacement (P = .03) and a lower polar angle value (P = .008); also, halogen glare discomfort was greater with a higher radius (P = .04). Using the pupil center as a reference, greater nasal central hole decentration was associated with longer xenon glare photostress recovery time (P = .002).

CONCLUSIONS

Implantation of the ICL with a central hole yielded excellent visual outcomes, even under increasing glare sources, regardless of the hole's location. However, hole decentration might affect patient-perceived quality of life, bothersome halogen glare, and longer xenon glare photostress recovery time. Such complaints after the early postoperative period might be managed with discrete ICL centration if the central hole is decentered upward or nasally.

摘要

目的

分析 V4c 可植入 Collamer 透镜(ICL)中央孔位置对视觉质量的影响,包括渐进式车头灯眩光模拟和生活质量。

地点

西班牙巴利亚多利德 IOBA-Eye 研究所。

设计

病例系列。

方法

术后 6 个月或更长时间,通过裂隙灯和双 Scheimpflug 成像确定中央孔位置。评估视力、中间光对比度敏感度、卤素眩光对比度敏感度、氙气眩光对比度敏感度、眩光后光应激恢复时间、de Boer 量表和屈光矫正生活质量影响(QIRC)问卷结果。使用多元回归模型,基于笛卡尔和极坐标,以瞳孔中心和视轴为参考,分析中央孔位置对参数的影响。

结果

安全指数为 1.13,有效指数为 1.12。在所有测试情况下,中央孔偏心都不会影响视力或对比度敏感度。以视轴为参考,向上中央孔位移越大(P=0.03)和极角值越低(P=0.008),QIRC 值越差;此外,较高的半径与更大的卤素眩光不适(P=0.04)相关。以瞳孔中心为参考,较大的鼻侧中央孔偏心与更长的氙气眩光光应激恢复时间相关(P=0.002)。

结论

即使在增加的眩光源下,ICL 中央孔的植入也能获得出色的视觉效果,无论孔的位置如何。然而,孔偏心可能会影响患者感知的生活质量、烦人的卤素眩光和更长的氙气眩光光应激恢复时间。如果中央孔向上或向鼻侧偏心,可以通过离散的 ICL 校准来管理术后早期的这些投诉。