Ivers Kevin M, Yang Hongli, Gardiner Stuart K, Qin Lirong, Reyes Luke, Fortune Brad, Burgoyne Claude F
Optic Nerve Head Research Laboratory, Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States 2Discoveries in Sight Research Laboratories of the Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States.
Discoveries in Sight Research Laboratories of the Devers Eye Institute, Legacy Research Institute, Portland, Oregon, United States.
Invest Ophthalmol Vis Sci. 2016 Jul 1;57(9):OCT388-403. doi: 10.1167/iovs.15-18666.
To compare optical coherence tomography (OCT) detected, optic nerve head (ONH) compliance within control and experimental glaucoma (EG) eyes of 15 monkeys at EG onset.
Intraocular pressure (IOP) was chronically elevated in one eye of each animal using a laser. Experimental glaucoma onset was identified using confocal scanning laser tomography (CSLT). Optical coherence tomography ONH imaging (40 radial B-scans) was performed at 10 mm Hg before and after laser. At EG onset, OCT scans were obtained at IOP 10 and 30 mm Hg. Optical coherence tomography landmarks within the IOP 10/30 images were delineated to quantify IOP 10/30 differences (compliance) for anterior lamina cribrosa surface depth (ALCSD) relative to Bruch's membrane opening (BMO) (ALCSD-BMO), ALCSD relative to peripheral BM (ALCSD-BM), and BMO depth relative to peripheral BM (BMOD-BM). A linear mixed effects model assessed for acute IOP elevation effects, control versus EG eye effects, and their interaction.
Effects of IOP elevation were greater in EG versus control eyes for ALCSD-BMO (-46 ± 45 vs. -8 ± 13 μm, P = 0.0042) and ALCSD-BM (-92 ± 64 vs. -42 ± 22 μm, P = 0.0075). Experimental glaucoma eye-specific ALCSD-BMO and ALCSD-BM compliance exceeded the range of control eye compliance in 9 and 8 of the 15 EG eyes, respectively. Post-laser peak IOP (R2 = 0.798, P < 0.0001) and post-laser mean IOP (R2 = 0.634, P < 0.0004) most strongly correlated to EG versus control eye differences in ALCSD-BMO compliance.
Laminar (ALCSD-BMO) and peripapillary scleral (ALCSD-BM) hypercompliance are present in most monkey eyes at the onset of EG.
比较光学相干断层扫描(OCT)检测的15只猴子在实验性青光眼(EG)发病时,其对照眼和实验性青光眼(EG)眼中视神经乳头(ONH)的顺应性。
使用激光使每只动物的一只眼睛眼压长期升高。使用共焦扫描激光断层扫描(CSLT)确定实验性青光眼发病。在激光治疗前后眼压为10 mmHg时进行光学相干断层扫描ONH成像(40条径向B扫描)。在EG发病时,在眼压为10和30 mmHg时获取OCT扫描图像。在眼压为10/30的图像中勾勒出光学相干断层扫描的标志,以量化相对于布鲁赫膜开口(BMO)的筛板前表面深度(ALCSD)(ALCSD - BMO)、相对于周边BM的ALCSD(ALCSD - BM)以及相对于周边BM的BMO深度(BMOD - BM)的眼压10/30差异(顺应性)。采用线性混合效应模型评估急性眼压升高的影响、对照眼与EG眼的影响及其相互作用。
对于ALCSD - BMO(-46 ± 45 vs. -8 ± 13 μm,P = 0.0042)和ALCSD - BM(-92 ± 64 vs. -42 ± 22 μm,P = 0.0075),EG眼中眼压升高的影响大于对照眼。在15只EG眼中,分别有9只和8只EG眼的实验性青光眼眼特异性ALCSD - BMO和ALCSD - BM顺应性超出了对照眼顺应性的范围。激光治疗后的峰值眼压(R2 = 0.798,P < 0.0001)和激光治疗后的平均眼压(R2 = 0.634,P < 0.0004)与EG眼和对照眼在ALCSD - BMO顺应性方面的差异相关性最强。
在EG发病时,大多数猴子眼中存在板层(ALCSD - BMO)和视乳头周围巩膜(ALCSD - BM)的高顺应性。