Fornaini Carlo, Merigo Elisabetta, Sozzi Michele, Rocca Jean-Paul, Poli Federica, Selleri Stefano, Cucinotta Annamaria
Information Engineering Department, University of Parma, Italy; MICORALIS Laboratory, Faculty of Dentistry, University of Nice, France.
MICORALIS Laboratory, Faculty of Dentistry, University of Nice, France.
Laser Ther. 2016 Jun 29;25(2):105-114. doi: 10.5978/islsm.16-OR-08.
The introduction of diode lasers in dentistry had several advantages, principally consisting on the reduced size, reduced cost and possibility to beam delivering by optical fibbers. Up today only the wavelengths around 810 and 980 nm were the most utilized in oral surgery but recently more different lasers had been proposed. The aim of this study was to compare the efficacy of four diode laser wavelengths (810, 980, 1470 and 1950 nm) for the ablation of soft tissues. Specimens were surgically collected from the dorsal surface of four bovine tongues and irradiated by four different diode wavelengths. Thermal increase was measured by two thermocouples, the first at a depth of 0.5 mm, and the second at a depth of 2 mm. Initial and final surface temperatures were recorded by IR thermometer. Epithelial changes, connective tissue modifications, presence of vascular modification and incision morphology were histologically evaluated by two blind pathologists. The time necessary to perform the excision varied between 271 seconds (808 nm, 2W) and 112 seconds (1950 nm, 4W). Temperature increase superficial level varied from 16.3° (980 nm, 4W) and 9.2° (1950 nm, 2 W). The most significant deep temperature increase was recorded by 980 nm, 4 W (17.3°) and the lowest by 1950 nm, 2 W (9.7°). The width of epithelial tissue injuries varied between 74 pm from 1950 nm diode laser at 2 W to 540 pm for 1470 nm diode laser at 4 W. The quality of incision was better and the width of overall tissue injuries was minor in the specimens obtained with higher wavelength (1950 nm) at lower power (2W).
牙科中二极管激光器的引入具有多个优点,主要包括尺寸减小、成本降低以及可通过光纤进行光束传输。到目前为止,仅810和980nm左右的波长在口腔外科中使用最为广泛,但最近已提出了更多不同的激光器。本研究的目的是比较四种二极管激光波长(810、980、1470和1950nm)对软组织消融的效果。从四个牛舌的背面手术采集标本,并用四种不同的二极管波长进行照射。用两个热电偶测量温度升高,第一个位于0.5mm深度处,第二个位于2mm深度处。用红外温度计记录初始和最终表面温度。由两名盲法病理学家对上皮变化、结缔组织改变、血管改变的存在情况以及切口形态进行组织学评估。进行切除所需的时间在271秒(808nm,2W)至112秒(1950nm,4W)之间变化。表面温度升高水平在16.3°(980nm,4W)至9.2°(1950nm,2W)之间变化。980nm,4W记录到的最深温度升高最为显著(17.3°),而1950nm,2W记录到的最低(9.7°)。上皮组织损伤的宽度在2W的1950nm二极管激光器产生的74μm至4W的1470nm二极管激光器产生的540μm之间变化。在较低功率(2W)下使用较高波长(1950nm)获得的标本中,切口质量更好,整体组织损伤的宽度更小。