Suppr超能文献

头颈部鳞状细胞癌患者的高级扩散模型:拟合优度、扩散参数之间的关系以及与动态对比增强灌注的比较

Advanced diffusion models in head and neck squamous cell carcinoma patients: Goodness of fit, relationships among diffusion parameters and comparison with dynamic contrast-enhanced perfusion.

作者信息

Fujima Noriyuki, Sakashita Tomohiro, Homma Akihiro, Shimizu Yukie, Yoshida Atsushi, Harada Taisuke, Tha Khin Khin, Kudo Kohsuke, Shirato Hiroki

机构信息

Department of Diagnostic and Interventional Radiology, Hokkaido University Hospital, Sapporo, Japan.

Department of Otolaryngology-Head and Neck Surgery, Hokkaido University Graduate School of Medicine, Sapporo, Japan.

出版信息

Magn Reson Imaging. 2017 Feb;36:16-23. doi: 10.1016/j.mri.2016.10.024. Epub 2016 Oct 27.

Abstract

PURPOSE

We assessed advanced fitting models of diffusion weighted imaging (DWI) in head/neck squamous cell carcinoma (HNSCC) patients to determine the best goodness of fit and correlations among diffusion parameters. We compared these results with those of dynamic contrast-enhanced (DCE) perfusion parameters.

MATERIALS AND METHODS

We retrospectively evaluated 32 HNSCC patients (12 sinonasal, 20 pharynx/oral cavity). The DWI acquisition used single-shot spin-echo echo-planar imaging (EPI) with 12 b-values (0-2000). We calculated 14 DWI parameters using mono-exponential, bi-exponential, and tri-exponential models, stretched exponential model (SEM) and diffusion kurtosis imaging (DKI) models. We compared each model's goodness of fit using the residual sum of squares (RSS), Akaike Information Criterion (AIC) and Bayesian information criterion (BIC) value. We determined the correlation between each pair of DWI parameters and between each DWI parameter and DCE perfusion parameter.

RESULTS

The tri-exponential fit's RSS, AIC and BIC values were significantly smaller than those for bi-exponential fit. The RSS, AIC and BIC values of the SEM fit and DKI fit were significantly smaller than mono-exponential model. Significant correlations were observed in 30 pairs (sinonasal cavity) and 31 (sinonasal cavity group) among 91 DWI parameter combinations. Significant correlations were also observed in nine pairs (both sinonasal cavity and pharynx/oral cavity group) among 64 DWI/DCE perfusion parameter pairs, in particular, high positive correlations between the tri-exponential model's intermediate diffusion fraction (f) and the volume of the extracellular extravascular space per unit volume of tissue (v) were observed in both patient groups.

CONCLUSION

We identified several correlations between DWI parameters by advanced fitting models and correlations between DWI and DCE parameters. These will help determine HNSCC patients' detailed tissue structures.

摘要

目的

我们评估了头颈部鳞状细胞癌(HNSCC)患者扩散加权成像(DWI)的高级拟合模型,以确定最佳拟合优度以及扩散参数之间的相关性。我们将这些结果与动态对比增强(DCE)灌注参数的结果进行了比较。

材料与方法

我们回顾性评估了32例HNSCC患者(12例鼻窦癌,20例咽/口腔癌)。DWI采集采用单次激发自旋回波平面成像(EPI),具有12个b值(0 - 2000)。我们使用单指数、双指数和三指数模型、拉伸指数模型(SEM)和扩散峰度成像(DKI)模型计算了14个DWI参数。我们使用残差平方和(RSS)、赤池信息准则(AIC)和贝叶斯信息准则(BIC)值比较了每个模型的拟合优度。我们确定了每对DWI参数之间以及每个DWI参数与DCE灌注参数之间的相关性。

结果

三指数拟合的RSS、AIC和BIC值显著小于双指数拟合。SEM拟合和DKI拟合的RSS、AIC和BIC值显著小于单指数模型。在91个DWI参数组合中,鼻窦腔组有30对、鼻窦腔组有31对存在显著相关性。在64个DWI/DCE灌注参数对中,鼻窦腔组和咽/口腔腔组均有9对存在显著相关性,特别是在两个患者组中均观察到三指数模型的中间扩散分数(f)与每单位组织体积的细胞外血管外间隙体积(v)之间存在高度正相关。

结论

我们通过高级拟合模型确定了DWI参数之间的几种相关性以及DWI与DCE参数之间的相关性。这些将有助于确定HNSCC患者的详细组织结构。