Schützenberger Anne, Kunduk Melda, Döllinger Michael, Alexiou Christoph, Dubrovskiy Denis, Semmler Marion, Seger Anja, Bohr Christopher
Division for Phoniatrics and Pediatric Audiology, Department of Otorhinolaryngology, Head and Neck Surgery, Medical School, FAU-Erlangen-Nürnberg, Bohlenplatz 21, 91054 Erlangen, Germany.
Department of Communication Sciences and Disorders, Louisiana State University, 64 Hatcher Hall, Baton Rouge, LA 70803, USA.
Biomed Res Int. 2016;2016:4575437. doi: 10.1155/2016/4575437. Epub 2016 Nov 21.
The current use of laryngeal high-speed videoendoscopy in clinic settings involves subjective visual assessment of vocal fold vibratory characteristics. However, objective quantification of vocal fold vibrations for evidence-based diagnosis and therapy is desired, and objective parameters assessing laryngeal dynamics have therefore been suggested. This study investigated the sensitivity of the objective parameters and their dependence on recording frame rate. A total of 300 endoscopic high-speed videos with recording frame rates between 1000 and 15 000 fps were analyzed for a vocally healthy female subject during sustained phonation. Twenty parameters, representing laryngeal dynamics, were computed. Four different parameter characteristics were found: parameters showing no change with increasing frame rate; parameters changing up to a certain frame rate, but then remaining constant; parameters remaining constant within a particular range of recording frame rates; and parameters changing with nearly every frame rate. The results suggest that (1) parameter values are influenced by recording frame rates and different parameters have varying sensitivities to recording frame rate; (2) normative values should be determined based on recording frame rates; and (3) the typically used recording frame rate of 4000 fps seems to be too low to distinguish accurately certain characteristics of the human phonation process in detail.
目前临床环境中喉高速视频内镜检查的应用涉及对声带振动特征的主观视觉评估。然而,需要对声带振动进行客观量化以用于循证诊断和治疗,因此有人提出了评估喉动力学的客观参数。本研究调查了这些客观参数的敏感性及其对记录帧率的依赖性。对一名嗓音健康的女性受试者在持续发声期间进行了分析,共分析了300段记录帧率在1000至15000帧/秒之间的内镜高速视频。计算了代表喉动力学的20个参数。发现了四种不同的参数特征:随着帧率增加而无变化的参数;在达到一定帧率之前变化但随后保持恒定的参数;在特定记录帧率范围内保持恒定的参数;以及几乎随每个帧率变化的参数。结果表明:(1)参数值受记录帧率影响,不同参数对记录帧率的敏感性不同;(2)应根据记录帧率确定标准值;(3)通常使用的4000帧/秒的记录帧率似乎过低,无法详细准确地区分人类发声过程的某些特征。