Diagnosis of early glaucoma with flicker comparisons of serial disc photographs.

作者信息

Heijl A, Bengtsson B

机构信息

Department of Ophthalmology in Malmö, University of Lund, Sweden.

出版信息

Invest Ophthalmol Vis Sci. 1989 Nov;30(11):2376-84.

PMID:2807794
Abstract

We evaluated flicker comparison, a technique for detecting differences in serial fundus photographs. Serial optic disc photographs and computerized threshold visual fields were obtained every 3 months for an average of 40 months in 131 eyes of 81 patients with elevated intraocular pressure and normal visual fields. Two serial monophotographs were projected, optically aligned, and superimposed; analysis was done by alternately viewing first one and then the other image. We found flicker analysis of serial disc photographs to provide results which were closely correlated with those of computerized threshold perimetry. Thus, of those 12 eyes which developed field defects, eight showed definite change and two showed highly suspected change in optic disc configuration. Only two eyes showed a definite alteration in optic disc anatomy without the development of field loss, and field defects appeared in only one of 109 eyes in which there was no change or suspected change on flicker comparison. The flicker method was more sensitive than conventional nonflickered comparisons, but changes could usually be seen also with conventional inspection once they had been detected by the flicker method. Our findings suggest that flicker analysis may offer a considerable improvement over current standard methods of analyzing serial photography and may be a useful complement to routine perimetry. However, this method requires special equipment; requires that the photographs be similarly centered; and is time-consuming. Alignment of photographs by means of computerized image analysis techniques could make the method clinically practicable.

摘要

我们评估了闪烁比较法,这是一种用于检测系列眼底照片差异的技术。在81例眼压升高且视野正常的患者的131只眼中,每3个月获取一次系列视盘照片和计算机化阈值视野,平均持续40个月。将两张系列单张照片进行投影、光学对齐并叠加;通过交替观看第一张和第二张图像进行分析。我们发现对系列视盘照片进行闪烁分析所得到的结果与计算机化阈值视野检查的结果密切相关。因此,在那些出现视野缺损的12只眼中,8只视盘形态有明确变化,2只视盘形态有高度可疑变化。只有2只眼视盘解剖结构有明确改变但未出现视野缺损,在109只经闪烁比较无变化或可疑变化的眼中,只有1只出现了视野缺损。闪烁法比传统的非闪烁比较法更敏感,但一旦通过闪烁法检测到变化,通常通过传统检查也能看到。我们的研究结果表明,闪烁分析可能比目前分析系列照片的标准方法有显著改进,并且可能是常规视野检查的有用补充。然而,这种方法需要特殊设备;要求照片具有相似的中心定位;而且耗时。通过计算机化图像分析技术对照片进行对齐可以使该方法在临床上可行。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验