传统X线片与电子根尖定位仪在确定C形根管工作长度中的评估

Evaluation of Conventional Radiography and an Electronic Apex Locator in Determining the Working Length in C-shaped Canals.

作者信息

Jafarzadeh Hamid, Beyrami Masoud, Forghani Maryam

机构信息

Dental Research Center and Department of Endodontics, Dental School, Mashhad University of Medical Sciences, Mashhad, Iran.

Private Practice, Tehran, Iran.

出版信息

Iran Endod J. 2017 Winter;12(1):60-63. doi: 10.22037/iej.2017.12.

Abstract

INTRODUCTION

The purpose of this study was to compare the accuracy of working length determination using the apex locator versus conventional radiography in C-shaped canals.

METHODS AND MATERIALS

After confirming the actual C-shaped anatomy using cone-beam computed tomography (CBCT), 22 extracted C-shaped mandibular second molars were selected and decoronated at the cemento-enamel junction. The actual working length of these canals were determined by inserting a #15 K-file until the tip could be seen through the apical foramen and the working length was established by subtracting 0.5 mm from this length. The working length was also determined using conventional analog radiography and electronic apex locator (EAL) that were both compared with the actual working length. The data was statistically analyzed using paired t-test and marginal homogeneity test.

RESULTS

There was no significant differences between the working length obtained with apex locator and that achieved through conventional radiography in terms of measuring the mesiolingual and distal canals (>0.05); while, significant differences were observed in measurements of the mesiobuccal canals (=0.036). Within ±0.5 mm of tolerance margin there was no significant difference between EAL and conventional radiography.

CONCLUSION

The apex locator was more accurate in determination of the working length of C-shaped canals compared with the conventional radiography.

摘要

引言

本研究的目的是比较在C形根管中使用根尖定位仪与传统放射照相法确定工作长度的准确性。

方法和材料

使用锥形束计算机断层扫描(CBCT)确认实际的C形解剖结构后,选择22颗拔除的下颌C形第二磨牙,并在牙骨质-釉质界处去除牙冠。通过插入一根#15 K锉直至其尖端可透过根尖孔看到来确定这些根管的实际工作长度,并从此长度减去0.5 mm来确定工作长度。还使用传统的模拟放射照相法和电子根尖定位仪(EAL)来确定工作长度,并将两者与实际工作长度进行比较。使用配对t检验和边际齐性检验对数据进行统计分析。

结果

在测量近中舌侧和远中根管时,根尖定位仪获得的工作长度与传统放射照相法获得的工作长度之间无显著差异(>0.05);而在测量近中颊侧根管时观察到显著差异(=0.036)。在±0.5 mm的公差范围内,EAL与传统放射照相法之间无显著差异。

结论

与传统放射照相法相比,根尖定位仪在确定C形根管工作长度方面更准确。

相似文献

4
Accuracy of the Dentaport ZX apex locator for working length determination when retreating molar root canals.
Aust Endod J. 2014 Apr;40(1):2-5. doi: 10.1111/aej.12010. Epub 2012 Dec 11.
5
Influence of Root Canal Curvature on the Accuracy of Root ZX Electronic Foramen Locator: An Study.
Iran Endod J. 2017 Spring;12(2):173-178. doi: 10.22037/iej.2017.34.
6
Evaluation of the Working Length Determination Accuracy by Cone-beam Computed Tomography in Primary Teeth.
Int J Clin Pediatr Dent. 2022;15(Suppl 1):S92-S96. doi: 10.5005/jp-journals-10005-2330.
7
Accuracy of working length measurement: electronic apex locator versus cone-beam computed tomography.
Int Endod J. 2014 Mar;47(3):246-56. doi: 10.1111/iej.12140. Epub 2013 Jun 17.
8
Comparison of Radiovisiography, an Apex Locator and an Integrated Endomotor-inbuilt Apex Locator in Primary Teeth Endometrics.
Int J Clin Pediatr Dent. 2022;15(Suppl 1):S18-S21. doi: 10.5005/jp-journals-10005-2123.

引用本文的文献

2
Endodontic Treatment of C-shaped Mandibular Premolars: A Case Report and Review of Literature.
Iran Endod J. 2021 Fall;16(4):244-253. doi: 10.22037/iej.v16i4.34187.
6
Accuracy of Four Apex Locators in Premolars with Root Resorption: An Study.
Iran Endod J. 2022 Winter;17(1):20-26. doi: 10.22037/iej.v17i1.35498.
7
The Effect of Long Service Life on the Accuracy of Dentaport ZX Electronic Apex Locator.
Iran Endod J. 2022;17(4):195-199. doi: 10.22037/iej.v17i4.34623.
9
Canal Straightening Following Overinstrumentation with Three Nickel-Titanium Rotary Instruments.
J Int Soc Prev Community Dent. 2018 May-Jun;8(3):245-251. doi: 10.4103/jispcd.JISPCD_18_18. Epub 2018 May 17.
10
Comparison of Tentative Radiographic Working Length with and without grid Versus Electronic Apex Locator.
Contemp Clin Dent. 2018 Jan-Mar;9(1):88-91. doi: 10.4103/ccd.ccd_790_17.

本文引用的文献

3
Use of electronic apex locators may improve determination of working length.
Evid Based Dent. 2014 Dec;15(4):120. doi: 10.1038/sj.ebd.6401066.
5
C-shaped root canal configuration: A review of literature.
J Conserv Dent. 2014 Jul;17(4):312-9. doi: 10.4103/0972-0707.136437.
7
Evaluation of the Raypex 5 and the Mini Apex Locator: an in vivo study.
J Endod. 2011 Oct;37(10):1349-52. doi: 10.1016/j.joen.2011.06.021. Epub 2011 Jul 30.
8
Effectiveness of four electronic apex locators to determine distance from the apical foramen.
Int Endod J. 2010 Sep;43(9):808-17. doi: 10.1111/j.1365-2591.2010.01765.x. Epub 2010 Aug 3.
9
An ex vivo comparison of root canal length determination by three electronic apex locators at positions short of the apical foramen.
Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2010 Aug;110(2):e57-61. doi: 10.1016/j.tripleo.2010.03.005. Epub 2010 Jun 23.
10
Microscopic investigation of root apexes. 1955.
J Indiana Dent Assoc. 2010 Spring;89(1):20-8.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验