Suppr超能文献

从心电图和光电容积脉搏波图中提取呼吸信号:技术和生理决定因素。

Extraction of respiratory signals from the electrocardiogram and photoplethysmogram: technical and physiological determinants.

作者信息

Charlton Peter H, Bonnici Timothy, Tarassenko Lionel, Alastruey Jordi, Clifton David A, Beale Richard, Watkinson Peter J

机构信息

School of Medicine, King's College London, United Kingdom. Department of Engineering Science, Institute of Biomedical Engineering, University of Oxford, United Kingdom.

出版信息

Physiol Meas. 2017 May;38(5):669-690. doi: 10.1088/1361-6579/aa670e. Epub 2017 Mar 15.

Abstract

OBJECTIVE

Breathing rate (BR) can be estimated by extracting respiratory signals from the electrocardiogram (ECG) or photoplethysmogram (PPG). The extracted respiratory signals may be influenced by several technical and physiological factors. In this study, our aim was to determine how technical and physiological factors influence the quality of respiratory signals.

APPROACH

Using a variety of techniques 15 respiratory signals were extracted from the ECG, and 11 from PPG signals collected from 57 healthy subjects. The quality of each respiratory signal was assessed by calculating its correlation with a reference oral-nasal pressure respiratory signal using Pearson's correlation coefficient.

MAIN RESULTS

Relevant results informing device design and clinical application were obtained. The results informing device design were: (i) seven out of 11 respiratory signals were of higher quality when extracted from finger PPG compared to ear PPG; (ii) laboratory equipment did not provide higher quality of respiratory signals than a clinical monitor; (iii) the ECG provided higher quality respiratory signals than the PPG; (iv) during downsampling of the ECG and PPG significant reductions in quality were first observed at sampling frequencies of  <250 Hz and  <16 Hz respectively. The results informing clinical application were: (i) frequency modulation-based respiratory signals were generally of lower quality in elderly subjects compared to young subjects; (ii) the qualities of 23 out of 26 respiratory signals were reduced at elevated BRs; (iii) there were no differences associated with gender.

SIGNIFICANCE

Recommendations based on the results are provided regarding device designs for BR estimation, and clinical applications. The dataset and code used in this study are publicly available.

摘要

目的

呼吸率(BR)可通过从心电图(ECG)或光电容积脉搏波描记图(PPG)中提取呼吸信号来估计。提取的呼吸信号可能会受到多种技术和生理因素的影响。在本研究中,我们的目的是确定技术和生理因素如何影响呼吸信号的质量。

方法

使用多种技术从心电图中提取了15个呼吸信号,并从57名健康受试者采集的PPG信号中提取了11个呼吸信号。通过使用皮尔逊相关系数计算每个呼吸信号与参考口鼻压力呼吸信号的相关性来评估其质量。

主要结果

获得了有助于设备设计和临床应用的相关结果。有助于设备设计的结果有:(i)与从耳部PPG提取的呼吸信号相比,从手指PPG提取的11个呼吸信号中有7个质量更高;(ii)实验室设备提供的呼吸信号质量并不高于临床监护仪;(iii)心电图提供的呼吸信号质量高于PPG;(iv)在对心电图和PPG进行下采样时,分别在采样频率<250 Hz和<16 Hz时首次观察到质量显著下降。有助于临床应用的结果有:(i)与年轻受试者相比,基于频率调制的呼吸信号在老年受试者中质量普遍较低;(ii)26个呼吸信号中有23个在呼吸率升高时质量下降;(iii)与性别无关。

意义

根据结果为呼吸率估计的设备设计和临床应用提供了建议。本研究中使用的数据集和代码可公开获取。