Suppr超能文献

手部和腕部光角测量法的可行性

Viability of Hand and Wrist Photogoniometry.

作者信息

Meals Clifton G, Saunders Rebecca J, Desale Sameer, Means Kenneth R

机构信息

1 The Curtis National Hand Center at MedStar Union Memorial Hospital, Baltimore, MD, USA.

出版信息

Hand (N Y). 2018 May;13(3):301-304. doi: 10.1177/1558944717702471. Epub 2017 Apr 9.

Abstract

BACKGROUND

No goniometric technique is both maximally convenient and completely accurate, although photogoniometry (ie, picture taking to facilitate digital angle measurement) shows promise in this regard. Our purpose was to test the feasibility and reliability of a photogoniometric protocol designed to measure wrist and digit range of motion in general.

METHODS

Two independent observers examined a sample of joints in both normal and abnormal hands according to a photogoniometric protocol. Interrater and intrarater correlation were calculated, and these measurements were compared with measurements made by a third independent examiner with a manual goniometer.

RESULTS

The photo-based measurements were reliable within and between observers; however, only a minority of these measurements were in agreement with manually collected values.

CONCLUSIONS

At present, photogoniometry is not an acceptable alternative to manual goniometry for determining wrist and digit range of motion in general. Joint-specific photogoniometry should be the subject of future study, as should relevant imaging and software technology.

摘要

背景

尽管摄影测角法(即拍照以方便进行数字角度测量)在这方面显示出前景,但尚无一种测角技术既极其方便又完全准确。我们的目的是测试一种旨在测量手腕和手指一般活动范围的摄影测角方案的可行性和可靠性。

方法

两名独立观察者根据摄影测角方案检查了正常和异常手部的关节样本。计算了观察者间和观察者内的相关性,并将这些测量结果与第三名独立检查者使用手动测角仪进行的测量结果进行了比较。

结果

基于照片的测量在观察者之间和内部都是可靠的;然而,这些测量结果中只有少数与手动收集的值一致。

结论

目前,对于一般情况下确定手腕和手指的活动范围,摄影测角法不是手动测角法可接受的替代方法。特定关节的摄影测角法以及相关的成像和软件技术应成为未来研究的主题。

相似文献

1
Viability of Hand and Wrist Photogoniometry.
Hand (N Y). 2018 May;13(3):301-304. doi: 10.1177/1558944717702471. Epub 2017 Apr 9.
3
Accuracy and reliability of three different techniques for manual goniometry for wrist motion: a cadaveric study.
J Hand Surg Am. 2009 Oct;34(8):1422-8. doi: 10.1016/j.jhsa.2009.06.002. Epub 2009 Aug 22.
4
Accuracy and Validity of Goniometer and Visual Assessments of Angular Joint Positions of the Hand and Wrist.
J Hand Surg Am. 2016 Apr;41(4):e21-35. doi: 10.1016/j.jhsa.2015.12.014. Epub 2016 Jan 20.
6
Smartphone photography utilized to measure wrist range of motion.
J Hand Surg Eur Vol. 2018 Feb;43(2):187-192. doi: 10.1177/1753193417729140. Epub 2017 Sep 5.
7
Is diagrammatic goniometry feasible for finger ROM evaluation and self-evaluation?
Clin Orthop Relat Res. 2013 Jun;471(6):1894-903. doi: 10.1007/s11999-012-2777-6. Epub 2013 Jan 5.
8
Wrist ROM measurements using smartphone photography: Reliability and validity.
Hand Surg Rehabil. 2020 Sep;39(4):261-264. doi: 10.1016/j.hansur.2020.02.004. Epub 2020 Mar 20.
10

引用本文的文献

1
Automatic range of motion measurement via smartphone images for telemedicine examination of the hand.
Sci Prog. 2023 Jan-Mar;106(1):368504231152740. doi: 10.1177/00368504231152740.
2
Smart Technology and Orthopaedic Surgery: Current Concepts Regarding the Impact of Smartphones and Wearable Technology on Our Patients and Practice.
Curr Rev Musculoskelet Med. 2021 Dec;14(6):378-391. doi: 10.1007/s12178-021-09723-6. Epub 2021 Nov 3.
3
The Telemedicine-Based Pediatric Examination of the Neck and Upper Limbs: A Narrative Review.
J Pain Res. 2021 Oct 11;14:3173-3192. doi: 10.2147/JPR.S336168. eCollection 2021.
4
Accuracy of Wearable Sensor Technology in Hand Goniometry: A Systematic Review.
Hand (N Y). 2023 Mar;18(2):340-348. doi: 10.1177/15589447211014606. Epub 2021 May 25.

本文引用的文献

1
A Comparison of Elbow Range of Motion Measurements: Smartphone-Based Digital Photography Versus Goniometric Measurements.
J Hand Surg Am. 2016 Apr;41(4):510-515.e1. doi: 10.1016/j.jhsa.2016.01.006. Epub 2016 Feb 13.
2
Accuracy and Validity of Goniometer and Visual Assessments of Angular Joint Positions of the Hand and Wrist.
J Hand Surg Am. 2016 Apr;41(4):e21-35. doi: 10.1016/j.jhsa.2015.12.014. Epub 2016 Jan 20.
3
Comparative analysis of photograph-based clinical goniometry to standard techniques.
Hand (N Y). 2015 Jun;10(2):248-53. doi: 10.1007/s11552-014-9702-2.
4
Mobile smartphone applications for body position measurement in rehabilitation: a review of goniometric tools.
PM R. 2014 Nov;6(11):1038-43. doi: 10.1016/j.pmrj.2014.05.003. Epub 2014 May 15.
6
Analysis of the reliability and reproducibility of goniometry compared to hand photogrammetry.
Acta Ortop Bras. 2012;20(3):139-49. doi: 10.1590/S1413-78522012000300003.
7
Design and evaluation of a low-cost instrumented glove for hand function assessment.
J Neuroeng Rehabil. 2012 Jan 17;9:2. doi: 10.1186/1743-0003-9-2.
8
A technique for graphical recording of range of motion using an improvised paper goniometer.
J Hand Ther. 2011 Oct-Dec;24(4):374-7. doi: 10.1016/j.jht.2011.05.003. Epub 2011 Aug 4.
9
Validity and reliability of using photography for measuring knee range of motion: a methodological study.
BMC Musculoskelet Disord. 2011 Apr 18;12:77. doi: 10.1186/1471-2474-12-77.
10
Development of finger-motion capturing device based on optical linear encoder.
J Rehabil Res Dev. 2011;48(1):69-82. doi: 10.1682/jrrd.2010.02.0013.