This article describes a 3D microfluidic paper-based analytical device that can be used to conduct an enzyme-linked immunosorbent assay (ELISA). The device comprises two parts: a sliding strip (which contains the active sensing area) and a structure surrounding the sliding strip (which holds stored reagents-buffers, antibodies, and enzymatic substrate-and distributes fluid). Running an ELISA involves adding sample (e.g. blood) and water, moving the sliding strip at scheduled times, and analyzing the resulting color in the sensing area visually or using a flatbed scanner. We demonstrate that this device can be used to detect C-reactive protein (CRP)-a biomarker for neonatal sepsis, pelvic inflammatory disease, and inflammatory bowel diseases-at a concentration range of 1-100ng/mL in 1000-fold diluted blood (1-100µg/mL in undiluted blood). The accuracy of the device (as characterized by the area under the receiver operator characteristics curve) is 89% and 83% for cut-offs of 10ng/mL (for neonatal sepsis and pelvic inflammatory disease) and 30ng/mL (for inflammatory bowel diseases) CRP in 1000-fold diluted blood respectively. In resource-limited settings, the device can be used as a part of a kit (containing the device, a fixed-volume capillary, a pre-filled tube, a syringe, and a dropper); this kit would cost ~ $0.50 when produced in large scale (>100,000 devices/week). This kit has the technical characteristics to be employed as a pre-screening tool, when combined with other data such as patient history and clinical signs.
本文描述了一种可用于进行酶联免疫吸附测定(ELISA)的 3D 微流控纸基分析装置。该装置由两部分组成:滑动条(包含活性传感区域)和包围滑动条的结构(容纳储存的试剂-缓冲液、抗体和酶底物,并分配流体)。进行 ELISA 实验包括添加样品(如血液)和水,按计划时间移动滑动条,并通过目测或使用平板扫描仪分析传感区域中的显色结果。我们证明,该装置可用于检测 C 反应蛋白(CRP)-一种新生儿败血症、盆腔炎和炎症性肠病的生物标志物,在 1000 倍稀释的血液(100 倍未稀释血液)中浓度范围为 1-100ng/mL。该装置的准确性(以接收者操作特征曲线下的面积为特征)分别为 89%和 83%,用于 1000 倍稀释血液中新生儿败血症和盆腔炎的 10ng/mL(CRP)和炎症性肠病的 30ng/mL(CRP)的截断值。在资源有限的环境下,该装置可用作试剂盒的一部分(包含装置、固定体积毛细管、预填充管、注射器和滴管);当大规模生产(每周超过 10 万个装置)时,该试剂盒的成本约为 0.50 美元。当与患者病史和临床体征等其他数据结合使用时,该试剂盒具有作为预筛选工具的技术特点。