维生素 E 弥散的超高相对分子质量聚乙烯颗粒对金黄色葡萄球菌诱导的炎症、凋亡和免疫反应的影响。

Effects of vitamin E-diffused highly cross-linked UHMWPE particles on inflammation, apoptosis and immune response against S. aureus.

机构信息

Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Department of Orthopaedic Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, China.

Harris Orthopaedic Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.

出版信息

Biomaterials. 2017 Oct;143:46-56. doi: 10.1016/j.biomaterials.2017.07.028. Epub 2017 Jul 24.


DOI:10.1016/j.biomaterials.2017.07.028
PMID:28759874
Abstract

Particle-induced osteolysis and periprosthetic joint infection (PJI) are closely associated with periprosthetic tissue immune function. The objective of this study was to determine the effects of polyethylene particles on inflammation and response against S. aureus. Effects that vitamin E-diffused cross-linked UHMWPE (VE-PE) particles had on apoptosis, inflammation, and bactericidal activities compared to virgin cross-linked UHMWPE (control PE) particles were examined. Murine RAW 264.7 macrophages exposed to VE-PE particles in vitro were less apoptotic, secreted less tumor necrosis factor (TNF)-α, and responded more effectively against lipopolysaccharide or S. aureus compared to control PE particles. Implantation of VE-PE particles in murine calvaria in vivo caused less reactive oxygen species generation, less apoptosis, and less osteolysis compared to control PE particles. Implantation of PE particles in mice calvaria for 28 days, followed by inoculation with S. aureus in the same site where PE particles were implanted, demonstrated enhanced S. aureus clearance in the VE-PE group at day 33 after inoculation. These findings indicate that VE-PE particles might be less inflammatory and might preserve innate immunity of local tissue, allowing for enhanced clearance of bacteria.

摘要

颗粒诱导性骨溶解和假体周围关节感染(PJI)与假体周围组织免疫功能密切相关。本研究旨在确定聚乙烯颗粒对炎症和金黄色葡萄球菌反应的影响。与 virgin cross-linked UHMWPE(对照 PE)颗粒相比,研究了维生素 E 扩散交联 UHMWPE(VE-PE)颗粒对细胞凋亡、炎症和杀菌活性的影响。体外暴露于 VE-PE 颗粒的小鼠 RAW 264.7 巨噬细胞凋亡较少,分泌的肿瘤坏死因子(TNF)-α较少,对脂多糖或金黄色葡萄球菌的反应更有效,与对照 PE 颗粒相比。与对照 PE 颗粒相比,VE-PE 颗粒在体内植入小鼠颅骨中引起的活性氧生成、细胞凋亡和骨溶解较少。在植入 PE 颗粒 28 天后,在同一部位接种金黄色葡萄球菌,在接种后第 33 天,VE-PE 组金黄色葡萄球菌的清除率增强。这些发现表明,VE-PE 颗粒可能炎症反应较小,并可能保留局部组织的固有免疫,从而增强细菌的清除。

相似文献

[1]
Effects of vitamin E-diffused highly cross-linked UHMWPE particles on inflammation, apoptosis and immune response against S. aureus.

Biomaterials. 2017-7-24

[2]
Vitamin E-diffused highly cross-linked UHMWPE particles induce less osteolysis compared to highly cross-linked virgin UHMWPE particles in vivo.

J Arthroplasty. 2014-9

[3]
Identification of IL-27 as potent regulator of inflammatory osteolysis associated with vitamin E-blended ultra-high molecular weight polyethylene debris of orthopedic implants.

Acta Biomater. 2019-3-14

[4]
Do crosslinking and vitamin E stabilization influence microbial adhesions on UHMWPE-based biomaterials?

Clin Orthop Relat Res. 2015-3

[5]
Impact of vitamin E-blended UHMWPE wear particles on the osseous microenvironment in polyethylene particle-induced osteolysis.

Int J Mol Med. 2016-12

[6]
Immunomodulatory Peptide IDR-1018 Decreases Implant Infection and Preserves Osseointegration.

Clin Orthop Relat Res. 2015-9

[7]
Interplay between surface properties of standard, vitamin E blended and oxidised ultra high molecular weight polyethylene used in total joint replacement and adhesion of Staphylococcus aureus and Escherichia coli.

Bone Joint J. 2014-4

[8]
Effects of vitamin E incorporation in polyethylene on oxidative degradation, wear rates, immune response, and infections in total joint arthroplasty: a review of the current literature.

Int Orthop. 2018-11-23

[9]
Differential apoptotic response of J774 macrophages to alumina and ultra-high-molecular-weight polyethylene particles.

J Orthop Res. 2002-1

[10]
Continuous infusion of UHMWPE particles induces increased bone macrophages and osteolysis.

Clin Orthop Relat Res. 2011-1

引用本文的文献

[1]
Chemical, Mechanical and Tribological Effects of Artificially Aging up to 6 Weeks on Virgin and Crosslinked UHMWPE Evaluated for a TKR Design.

Bioengineering (Basel). 2025-7-24

[2]
The addition of vitamin E could reduce femoral head penetration of the polyethylene liners.

J Orthop Surg Res. 2025-1-20

[3]
Mechanism of regulating macrophages/osteoclasts in attenuating wear particle-induced aseptic osteolysis.

Front Immunol. 2023

[4]
Improving osteoinduction and osteogenesis of Ti6Al4V alloy porous scaffold by regulating the pore structure.

Front Chem. 2023-5-17

[5]
Macrophage-derived exosomes modulate wear particle-induced osteolysis via miR-3470b targeting TAB3/NF-κB signaling.

Bioact Mater. 2023-8

[6]
Current Knowledge on Biomaterials for Orthopedic Applications Modified to Reduce Bacterial Adhesive Ability.

Antibiotics (Basel). 2022-4-15

[7]
Extracellular Vesicles from Human Urine-Derived Stem Cells Ameliorate Particulate Polyethylene-Induced Osteolysis.

Int J Nanomedicine. 2021

[8]
Femoral head penetration in Vitamin-E polyethylene liner versus conventional liners in total hip arthroplasty: systematic review and meta-analysis of randomised control trials.

SICOT J. 2021

[9]
Toward a Better Regeneration through Implant-Mediated Immunomodulation: Harnessing the Immune Responses.

Adv Sci (Weinh). 2021-8

[10]
Interleukin-4 protects mice against lethal influenza and Streptococcus pneumoniae co-infected pneumonia.

Clin Exp Immunol. 2021-9