Fernández-Vega Cueto Luis, Lisa Carlos, Madrid-Costa David, Merayo-Lloves Jesús, Alfonso José F
Fernández-Vega Ophthalmological Institute, Oviedo, Spain.
Optics II Department, Optics and Optometry Faculty, Complutense University of Madrid, Madrid, Spain.
J Ophthalmol. 2017;2017:4058026. doi: 10.1155/2017/4058026. Epub 2017 Aug 29.
To assess the long-term outcomes of implanting intrastromal corneal ring segments (ICRS) in paracentral keratoconic eyes.
58 eyes with paracentral keratoconus with coincident refractive, keratometric, and comatic axes were evaluated. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity and refractive errors were recorded before and at all follow-up visits. The postoperative follow-up was 5 years. Patients were divided into two groups: group I (30 years old or younger) and group II (more than 30 years old).
The mean UDVA (logMAR) rose from a preoperative 0.83 ± 0.31 to a five-year postoperative 0.42 ± 0.33 ( < 0.0001). The mean CDVA varied from 0.16 ± 0.17 to 0.11 ± 0.18 ( = 0.0003). Both the UDVA and CDVA were stable over the postoperative period in both groups ( > 0.05). The spherical equivalent and the refractive cylinder declined steeply after ICRS implantation in both groups ( < 0.001), and were stable over the postoperative period ( > 0.05). The keratometric values were also stable over the postoperative follow-up.
Ferrara-type ICRS implantation in keratoconus that meets the characteristics of the sample under study reduces the refractive error at the same time as it improves postoperative UDVA and CDVA six months after surgery and that these results remain stable over five years of follow-up.
评估在角膜圆锥中央旁植入角膜基质环片(ICRS)的长期效果。
对58只角膜圆锥中央旁且屈光、角膜曲率和彗差轴一致的眼睛进行评估。记录术前及所有随访时的未矫正(UDVA)和矫正(CDVA)远视力及屈光不正情况。术后随访5年。患者分为两组:I组(30岁及以下)和II组(30岁以上)。
平均UDVA(logMAR)从术前的0.83±0.31提高到术后5年的0.42±0.33(<0.0001)。平均CDVA从0.16±0.17变化至0.11±0.18(=0.0003)。两组术后UDVA和CDVA在整个随访期均保持稳定(>0.05)。两组植入ICRS后等效球镜度和屈光柱镜度均急剧下降(<0.001),且术后保持稳定(>0.05)。角膜曲率值在术后随访中也保持稳定。
对于符合本研究样本特征的圆锥角膜患者,植入费拉拉型ICRS可在术后6个月改善UDVA和CDVA的同时降低屈光不正,且这些结果在5年随访期内保持稳定。