黄斑完整性评估与2型黄斑毛细血管扩张症椭圆体带光学相干断层扫描成像之间的相关性

Correlation Between Macular Integrity Assessment and Optical Coherence Tomography Imaging of Ellipsoid Zone in Macular Telangiectasia Type 2.

作者信息

Mukherjee Dibyendu, Lad Eleonora M, Vann Ryan R, Jaffe Stephanie J, Clemons Traci E, Friedlander Martin, Chew Emily Y, Jaffe Glenn J, Farsiu Sina

机构信息

Department of Biomedical Engineering, Duke University Medical Center, Durham, North Carolina, United States.

Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina, United States.

出版信息

Invest Ophthalmol Vis Sci. 2017 May 1;58(6):BIO291-BIO299. doi: 10.1167/iovs.17-21834.

Abstract

PURPOSE

To correlate ellipsoid zone (EZ) defects on spectral-domain optical coherence tomography (SD-OCT) with retinal sensitivity loss on macular integrity assessment (MAIA) microperimetry in macular telangiectasia type 2 (MacTel).

METHODS

Macular SD-OCT volumes and microperimetry maps were obtained during the international, multicenter, randomized phase 2 trial of ciliary neurotrophic factor for type 2 MacTel on two visits within 5 days of one another. Software was developed to register SD-OCT to MAIA scanning laser ophthalmoscopy images and to overlay EZ defect areas on the microperimetry maps generated from microperimetry sensitivity values at specific points and from interpolated sensitivity values. A total of 134 eyes of 67 patients were investigated.

RESULTS

The semiautomated registration algorithm was found to be accurate, both qualitatively by visual inspection of the nearly perfect overlap of the retinal vessels and quantitatively as assessed by interobserver reliability metrics performed in 98 eyes of 49 patients (intraclass correlation of aggregate retinal sensitivity loss >0.99). Aggregate retinal sensitivity loss within the EZ defect area was highly correlated with EZ defect area (Pearson correlation coefficient 0.93 and 0.92 at screening and baseline for noninterpolated maps; both were 0.94 for interpolated maps; P values <0.001).

CONCLUSIONS

With our software and image processing algorithms, there is nearly perfect correlation between retinal sensitivity on microperimetry and EZ defect area on SD-OCT. Our software allows determination of functional and structural changes with increasing disease severity and demonstrates that functional loss on microperimetry may be used as a surrogate marker of EZ loss on SD-OCT in type 2 MacTel.

摘要

目的

在2型黄斑毛细血管扩张症(MacTel)中,将光谱域光学相干断层扫描(SD-OCT)上的椭圆体带(EZ)缺陷与黄斑完整性评估(MAIA)微视野检查中的视网膜敏感度损失相关联。

方法

在国际多中心随机2期睫状神经营养因子治疗2型MacTel试验期间,在彼此间隔5天的两次就诊时获取黄斑SD-OCT容积和微视野检查图。开发了软件,用于将SD-OCT与MAIA扫描激光检眼镜图像配准,并将EZ缺陷区域叠加在由特定点的微视野敏感度值和插值敏感度值生成的微视野检查图上。共对67例患者的134只眼进行了研究。

结果

发现半自动配准算法是准确的,通过目视检查视网膜血管几乎完美重叠进行定性评估,通过对49例患者的98只眼进行观察者间可靠性指标评估进行定量评估(总体视网膜敏感度损失的组内相关性>0.99)。EZ缺陷区域内的总体视网膜敏感度损失与EZ缺陷区域高度相关(筛查和基线时,非插值图的Pearson相关系数分别为0.93和0.92;插值图均为0.94;P值<0.001)。

结论

使用我们的软件和图像处理算法,微视野检查中的视网膜敏感度与SD-OCT上的EZ缺陷区域之间几乎完全相关。我们的软件可以确定随着疾病严重程度增加的功能和结构变化,并表明微视野检查中的功能损失可作为2型MacTel中SD-OCT上EZ损失的替代标志物。