Suppr超能文献

通过光线追踪比较模拟角膜曲率计与总角膜屈光力:人工晶状体屈光力预测准确性的比较

Simulated Keratometry Versus Total Corneal Power by Ray Tracing: A Comparison in Prediction Accuracy of Intraocular Lens Power.

作者信息

Savini Giacomo, Hoffer Kenneth J, Lomoriello Domenico Schiano, Ducoli Pietro

机构信息

*Fondazione G.B. Bietti IRCCS, Rome, Italy;†Stein Eye Institute, University of California, Los Angeles, CA; and‡St. Mary's Eye Center, Santa Monica, CA.

出版信息

Cornea. 2017 Nov;36(11):1368-1372. doi: 10.1097/ICO.0000000000001343.

Abstract

PURPOSE

To investigate the relationship between corneal powers measured by simulated keratometry (Sim-K) and ray tracing and understand whether their difference influences intraocular lens (IOL) power calculation.

METHODS

In a first sample of healthy eyes, corneal curvature was measured using a rotating Scheimpflug camera (Sirius, CSO). Sim-K was obtained from anterior corneal curvature using the 1.3375 keratometric index. Ray tracing was performed through both corneal surfaces to calculate the total corneal power (TCP). The difference between Sim-K and TCP was correlated with various parameters. In a second sample of patients undergoing cataract surgery, IOL power was subsequently calculated using both Sim-K and TCP.

RESULTS

In the first sample (114 eyes), Sim-K (43.64 ± 1.44 D) was higher than TCP (43.07 ± 1.41 D, P < 0.0001); the difference ranged between 0.07 and 1.95 D and correlated with the anterior/posterior (A/P) ratio (r = 0.7292, P < 0.0001), which ranged between 1.10 and 1.30. In the second sample (107 eyes), the A/P ratio influenced the outcomes of the Holladay 1 and SRK/T, but not Haigis and Hoffer Q formulas. However, using TCP, which takes the A/P ratio into account, did not improve the prediction error of any formula.

CONCLUSIONS

Sim-K provides a higher corneal power compared with TCP. This difference is not constant but depends on the A/P ratio and can influence the refractive outcome of IOL power calculation by theoretical formulas. However, TCP values do not improve the results of these formulas, as they were developed for keratometric values such as Sim-K.

摘要

目的

研究模拟角膜曲率计(Sim-K)测量的角膜屈光力与光线追迹之间的关系,并了解它们之间的差异是否会影响人工晶状体(IOL)屈光力的计算。

方法

在健康眼睛的第一个样本中,使用旋转式Scheimpflug相机(Sirius,CSO)测量角膜曲率。使用1.3375的角膜曲率计指数从前角膜曲率获得Sim-K。通过两个角膜表面进行光线追迹以计算总角膜屈光力(TCP)。Sim-K与TCP之间的差异与各种参数相关。在接受白内障手术的患者的第二个样本中,随后使用Sim-K和TCP计算IOL屈光力。

结果

在第一个样本(114只眼)中,Sim-K(43.64±1.44 D)高于TCP(43.07±1.41 D,P<0.0001);差异范围在0.07至1.95 D之间,并与前后(A/P)比相关(r = 0.7292,P<0.0001),A/P比范围在1.10至1.30之间。在第二个样本(107只眼)中,A/P比对Holladay 1和SRK/T的结果有影响,但对Haigis和Hoffer Q公式没有影响。然而,使用考虑了A/P比的TCP并没有改善任何公式的预测误差。

结论

与TCP相比,Sim-K提供的角膜屈光力更高。这种差异不是恒定的,而是取决于A/P比,并且可以通过理论公式影响IOL屈光力计算的屈光结果。然而,TCP值并不能改善这些公式的结果,因为它们是针对诸如Sim-K的角膜曲率计值开发的。