Moussa Magdy, Leila Mahmoud, Khalid Hagar
Ophthalmology Department, Faculty of Medicine, Tanta University, Tanta, Egypt.
MEDIC Eye Center, Tanta, Egypt.
Clin Ophthalmol. 2017 Oct 13;11:1859-1869. doi: 10.2147/OPTH.S143018. eCollection 2017.
The aim of this study was to assess the efficacy of swept-source optical coherence tomography angiography (SS-OCTA) in delineating the morphology of choroidal neovascular membrane (CNV).
This was a retrospective observational case series reviewing clinical data and fundus fluorescein angiography (FFA), swept-source optical coherence tomography (SS-OCT), and SS-OCTA images of patients with CNV and comparing the findings. The swept-source technology enables deeper penetration and superior axial resolution. The incorporated blood flow detection algorithm, optical coherence tomography angiography ratio analysis (OCTARA), enables visualization of CNV in vivo without the need for dye injection.
The study included 136 eyes of 105 patients. Active lesions on SS-OCTA images showed increased capillary density, extensive arborization, vascular anastomosis and looping, and peri-lesional hollow. Inactive lesions showed decreased capillary density, presence of large linear vessels, and presence of feeder vessels supplying the CNV. We detected positive correlation between SS-OCTA, FFA, and SS-OCT images in 97% of eyes. In the remaining 3%, SS-OCTA confirmed the absence of CNV, whereas FFA and SS-OCT either were inconclusive in the diagnosis of CNV or yielded false-positive results.
SS-OCT and SS-OCTA represent a reproducible risk-free analog for FFA in imaging CNV. SS-OCTA is particularly versatile in cases where FFA and SS-OCT are inconclusive.
本研究旨在评估扫频源光学相干断层扫描血管造影(SS-OCTA)在描绘脉络膜新生血管膜(CNV)形态方面的有效性。
这是一项回顾性观察病例系列研究,回顾了CNV患者的临床数据、眼底荧光血管造影(FFA)、扫频源光学相干断层扫描(SS-OCT)及SS-OCTA图像,并对结果进行比较。扫频源技术能够实现更深的穿透深度和更高的轴向分辨率。所采用的血流检测算法,即光学相干断层扫描血管造影比率分析(OCTARA),能够在无需注射染料的情况下实现CNV的活体可视化。
该研究纳入了105例患者的136只眼。SS-OCTA图像上的活动性病变表现为毛细血管密度增加、广泛分支、血管吻合及迂曲,以及病变周围空洞。非活动性病变表现为毛细血管密度降低、存在大的线性血管以及存在供应CNV的供养血管。我们在97%的眼中检测到SS-OCTA、FFA及SS-OCT图像之间存在正相关。在其余3%的眼中,SS-OCTA证实不存在CNV,而FFA和SS-OCT在CNV诊断中要么不确定,要么得出假阳性结果。
SS-OCT和SS-OCTA是用于CNV成像的、可重复且无风险的类似FFA的检查方法。在FFA和SS-OCT不确定的情况下,SS-OCTA尤其适用。