急性眼压升高对大鼠视网膜对闪烁刺激的功能和血流反应的影响。

The Effect of Acutely Elevated Intraocular Pressure on the Functional and Blood Flow Responses of the Rat Retina to Flicker Stimulation.

作者信息

Tan Bingyao, MacLellan Benjamin, Mason Erik, Bizheva Kostadinka K

机构信息

Department of Physics and Astronomy, University of Waterloo, Waterloo, Ontario, Canada.

School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.

出版信息

Invest Ophthalmol Vis Sci. 2017 Oct 1;58(12):5532-5540. doi: 10.1167/iovs.17-22412.

Abstract

PURPOSE

To evaluate the effect of acutely elevated intraocular pressure (IOP) on the functional and blood flow responses of the rat retina to flicker stimulation.

METHODS

Brown Norway (n = 15) rats were dark-adapted before ketamine/xylazine anesthesia. IOP was raised acutely in one eye to ∼45 mm Hg with a vascular loop. In 11 rats, white light flicker stimulus (10 Hz, 2 seconds duration, 0.80 log scotopic cd·s/m2) was applied before and during IOP elevation, and 10 minutes after loop removal. Changes in the total retinal blood flow (TRBF) and retinal function induced by the visual stimulus were measured simultaneously with a combined optical coherence tomography (OCT) + electroretinography (ERG) system. Systemic blood pressure was measured in the remaining four rats frequently from 10 to 90 minutes post anesthesia injection.

RESULTS

The systemic blood pressure remained at 99 ± 4 mm Hg throughout the measurements (n = 4). Under normal IOP, the TRBF was 5.6 ± 1.9 μL/min, and the average retinal blood vessel size (BVS) in the vicinity of the optic nerve head (ONH) was 44.1 ± 4.5 μm. During IOP elevation, the TRBF was significantly lower (3.8 ± 1.2 μL/min, P < 0.01) and the BVS was significantly smaller (35.1 ± 2.6 μm, P < 0.01). Both TRBF and BVS returned to baseline within ∼10 minutes from removal of the vascular loop. The flicker-induced TRBF change measured under normal IOP (6.0 ± 3.3%) was reduced significantly to 0.1 ± 0.3% (P < 0.01) during IOP elevation, and recovered to 5.9 ± 1.7% within 10 minutes after loop removal. During IOP elevation, the magnitude of the ERG second harmonic component (SHC) decreased to 55% of its baseline value (P < 0.01) and remained significantly smaller than baseline (P < 0.01).

CONCLUSIONS

Acute IOP elevation to 45 mm Hg caused suppression of the retinal functional and TRBF response to flicker stimulation.

摘要

目的

评估急性眼压升高对大鼠视网膜功能及血流对闪烁刺激反应的影响。

方法

15只挪威棕色大鼠在氯胺酮/赛拉嗪麻醉前进行暗适应。用血管环将一只眼睛的眼压急性升高至约45毫米汞柱。11只大鼠在眼压升高前、升高期间以及移除血管环10分钟后施加白光闪烁刺激(10赫兹,持续2秒,0.80对数暗视cd·s/m²)。使用光学相干断层扫描(OCT)+视网膜电图(ERG)联合系统同时测量视觉刺激引起的视网膜总血流量(TRBF)和视网膜功能变化。对其余4只大鼠在麻醉注射后10至90分钟频繁测量其全身血压。

结果

在整个测量过程中,全身血压维持在99±4毫米汞柱(n = 4)。在正常眼压下,TRBF为5.6±1.9微升/分钟,视神经乳头(ONH)附近的平均视网膜血管大小(BVS)为44.1±4.5微米。眼压升高期间,TRBF显著降低(3.8±1.2微升/分钟,P < 0.01),BVS显著变小(35.1±2.6微米,P < 0.01)。从移除血管环起约10分钟内,TRBF和BVS均恢复至基线水平。在正常眼压下测量的闪烁诱导TRBF变化(6.0±3.3%)在眼压升高期间显著降低至0.1±0.3%(P < 0.01),并在移除血管环10分钟内恢复至5.9±1.7%。眼压升高期间,ERG二次谐波分量(SHC)的幅度降至其基线值的55%(P < 0.01),且仍显著低于基线(P < 0.01)。

结论

急性眼压升高至45毫米汞柱会抑制视网膜功能及TRBF对闪烁刺激的反应。