Department of Clinical Biochemistry, Bursa Yuksek Ihtisas Faculty, Saglik Bilimleri University, Bursa, Turkey.
Biochem Med (Zagreb). 2017 Oct 15;27(3):030708. doi: 10.11613/BM.2017.030708.
The quality of blood ethanol concentration (BEC) determination is important because of its legal ramifications. Measurement uncertainty provides quantitative information about the quality and reliability of test results. In this study, we aim to calculate the measurement uncertainty for the ethanol test in our laboratory measured with a Synchron Systems Ethanol assay kit by employing an enzymatic rate method on the Beckman-Coulter Olympus AU400 auto analyzer (Beckman Coulter Inc, Melville, USA).
The measurement uncertainty values were calculated in accordance to the Nordtest guidelines. All vehicle drivers involved in a traffic accident were retrospectively inspected for the BEC test conducted during July to December 2016 in our emergency laboratory.
A 1034 vehicle drivers had their BEC tested. The results for 181 drivers were > 0.50 g/L and reported as positive. The serum ethanol concentration in those showing a positive result was 2.04 ± 1.01 g/L, over four times the legal limit. The median BEC in those showing a negative result was 0.03 (IQR: 0.03) g/L. The expanded uncertainty obtained was 19.74%. When measurement uncertainty values were added to the results of the 1034 drivers who were retrospectively screened, eight vehicle drivers had results with 95% confidence intervals that exceeded the legal limit 0.50 g/L.
The BEC test results for vehicle drivers with values close to legal limits should be reported as the obtained ethanol concentration with corresponding measurement uncertainty.
由于涉及法律后果,血液乙醇浓度(BEC)测定的质量很重要。测量不确定度为测试结果的质量和可靠性提供了定量信息。本研究旨在通过贝克曼库尔特奥林巴斯 AU400 自动分析仪(贝克曼库尔特公司,美国梅尔维尔)上的酶速率法,使用同步系统乙醇分析试剂盒,计算我们实验室中乙醇测试的测量不确定度。
根据 Nordtest 指南计算测量不确定度值。对 2016 年 7 月至 12 月期间在我们急诊实验室进行 BEC 测试的所有涉及交通事故的驾驶员进行回顾性检查。
有 1034 名驾驶员进行了 BEC 测试。有 181 名驾驶员的结果> 0.50 g/L 并报告为阳性。阳性结果中血清乙醇浓度为 2.04 ± 1.01 g/L,超过法定限值的四倍。阴性结果中血清乙醇浓度中位数为 0.03(IQR:0.03)g/L。获得的扩展不确定度为 19.74%。当将测量不确定度值添加到回顾性筛选的 1034 名驾驶员的结果中时,有 8 名驾驶员的结果在 95%置信区间内超过了 0.50 g/L 的法定限值。
对于接近法定限值的驾驶员 BEC 测试结果,应报告为获得的乙醇浓度及其相应的测量不确定度。