Suppr超能文献

采用 T2 预平衡 3D 涡轮自旋回波序列对腰骶丛进行高各向同性分辨率 T2 映射。

High Isotropic Resolution T2 Mapping of the Lumbosacral Plexus with T2-Prepared 3D Turbo Spin Echo.

机构信息

Department of Diagnostic and Interventional Neuroradiology, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.

Department of Neurosurgery, Klinikum rechts der Isar, Technische Universität München, Ismaninger Str. 22, 81675, Munich, Germany.

出版信息

Clin Neuroradiol. 2019 Jun;29(2):223-230. doi: 10.1007/s00062-017-0658-9. Epub 2018 Jan 10.

Abstract

PURPOSE

Isotropic high-resolution three-dimensional (3D) magnetic resonance neurography (MRN) is increasingly used to depict even small and highly oblique nerves of the lumbosacral plexus (LSP). The present study introduces a T2 mapping sequence (T2-prepared 3D turbo spin echo) that is B1-insensitive and enables quantitative assessment of LSP nerves.

METHODS

In this study 15 healthy subjects (mean age 28.5 ± 3.8 years) underwent 3 T MRN of the LSP area three times. The T2 values were calculated offline on a voxel-by-voxel basis and measured at three segments (preganglionic, ganglionic, postganglionic) of three LSP nerves (S1, L5, L4) by two independent investigators (experienced and novice). Normative data for the different nerves were extracted and intraclass correlation coefficients (ICCs) were calculated to assess reproducibility and interobserver reliability of T2 measurements.

RESULTS

The T2 mapping showed excellent reproducibility with ICCs ranging between 0.99 (S1 preganglionic) and 0.89 (L5 postganglionic). Interobserver reliability was less robust with ICCs ranging between 0.78 (S1 preganglionic) and 0.44 (L5 postganglionic) for S1 and L5. A mean T2 value of 74.6 ± 4.7 ms was registered for preganglionic segments, 84.7 ± 4.1 ms for ganglionic and 65.4 ± 2.5 ms for postganglionic segments, respectively. There was a statistically significant variation of T2 values across the nerve (preganglionic vs ganglionic vs postganglionic) for S1, L5, and L4.

CONCLUSION

Our approach enables isotropic high-resolution and B1-insensitive T2 mapping of LSP nerves with excellent reproducibility. It might reflect a robust and clinically useful method for future diagnostics of LSP pathologies.

摘要

目的

各向同性高分辨率三维(3D)磁共振神经成像(MRN)越来越多地用于描绘腰骶丛(LSP)中即使是小而高度倾斜的神经。本研究介绍了一种 T2 映射序列(T2 准备的 3D 涡轮回波),该序列对 B1 不敏感,能够对 LSP 神经进行定量评估。

方法

本研究中,15 名健康受试者(平均年龄 28.5±3.8 岁)在 3T 磁共振下进行了 3 次 LSP 区域的 MRN。离线在体素基础上计算 T2 值,并由两名独立的观察者(经验丰富的和新手)在三个 LSP 神经(S1、L5、L4)的三个节段(节前、节内、节后)进行测量。提取不同神经的正常参考值,并计算了 T2 测量的组内相关系数(ICC),以评估 T2 测量的可重复性和观察者间可靠性。

结果

T2 映射显示出极好的可重复性,ICC 范围为 0.99(S1 节前)至 0.89(L5 节后)。观察者间的可靠性稍差,ICC 范围为 0.78(S1 节前)至 0.44(L5 节后),用于 S1 和 L5。记录到节前节段的平均 T2 值为 74.6±4.7ms,节内节段为 84.7±4.1ms,节后节段为 65.4±2.5ms。S1、L5 和 L4 的神经中 T2 值存在统计学显著差异(节前与节内与节后)。

结论

我们的方法能够对 LSP 神经进行各向同性高分辨率和 B1 不敏感的 T2 映射,具有极好的可重复性。它可能反映了一种稳健且在临床上有用的方法,可用于未来的 LSP 病理诊断。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/6a13/6579865/b274cd0fb6d1/62_2017_658_Fig1_HTML.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验