Suppr超能文献

50 岁以上人群中,示波法中心血压和中心收缩压负荷的可靠性:体位和禁食的影响。

Reliability of oscillometric central blood pressure and central systolic loading in individuals over 50 years: Effects of posture and fasting.

机构信息

Department of Sport & Exercise, University of Winchester, UK.

Department of Exercise and Sport Science, University of North Carolina at Chapel Hill, NC, USA.

出版信息

Atherosclerosis. 2018 Feb;269:79-85. doi: 10.1016/j.atherosclerosis.2017.12.030. Epub 2017 Dec 27.

Abstract

BACKGROUND AND AIMS

The between-day reliability of oscillometric pulse wave analysis has been demonstrated in a young, healthy population but not in an older sample. This study examined the between-day reliability of the SphygmoCor XCEL in individuals over 50 years. As blood pressure is measured in a range of postures and fasting states (supine/seated, fasted/non-fasted), this study also investigated the effect of these variables on central blood pressure and central systolic loading.

METHODS

Fifty-one adults (m = 21; age 57 ± 6.4 y) were tested on three mornings in supine and seated conditions and in fasted and non-fasted states. Data was analysed as a whole and for normotensive (n = 25) and hypertensive participants (n = 26).

RESULTS

SphygmoCor XCEL demonstrated strong reliability in the whole sample for central systolic and diastolic blood pressures, augmentation index (AIx) and AIx75 (ICC = 0.77-0.95). Significant interaction effects were observed in central diastolic blood pressure, central pulse pressure, augmentation index (AIx) and AIx75 (p < 0.05; η = 0.10-0.23). Fasting state had a greater influence on central pressures in a seated than supine posture, but a greater effect on central systolic loading measures in a supine posture.

CONCLUSIONS

The SphygmoCor XCEL is a reliable tool to assess central haemodynamic variables in an older population. It would be pertinent for clinicians and researchers to record central measures in a supine posture to minimise the effects of food consumption. Conversely, the assessment of central systolic loading should occur in a seated condition to minimise the influence of varying fasting states.

摘要

背景与目的

袖带式血压脉搏波分析的日间重复性已在年轻、健康人群中得到证实,但在老年人群中尚未得到证实。本研究旨在检测 SphygmoCor XCEL 在 50 岁以上人群中的日间重复性。由于血压是在多种体位和禁食状态下(仰卧/坐姿、禁食/非禁食)进行测量的,因此本研究还探讨了这些变量对中心血压和中心收缩负荷的影响。

方法

51 名成年人(男 21 名;年龄 57±6.4 岁)分别在三个早上进行仰卧位和坐姿、禁食和非禁食状态下的测试。数据分析包括整体分析以及正常血压组(n=25)和高血压组(n=26)的分析。

结果

SphygmoCor XCEL 在整个样本中对中心收缩压和舒张压、增强指数(AIx)和 AIx75 具有很强的可靠性(ICC=0.77-0.95)。在中心舒张压、中心脉压、增强指数(AIx)和 AIx75 中观察到显著的交互作用效应(p<0.05;η=0.10-0.23)。与仰卧位相比,禁食状态对坐姿下的中心血压影响更大,但对仰卧位下的中心收缩负荷指标影响更大。

结论

SphygmoCor XCEL 是评估老年人群中心血管动力学变量的可靠工具。对于临床医生和研究人员来说,记录仰卧位的中心测量值以最小化食物摄入的影响是很重要的。相反,应在坐姿下评估中心收缩负荷,以最小化不同禁食状态的影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验