Suppr超能文献

利用亨氏单位评估腰椎后路稳定及融合对稳定节段和相邻节段椎体骨密度的影响。

Assessing the effects of lumbar posterior stabilization and fusion to vertebral bone density in stabilized and adjacent segments by using Hounsfield unit.

作者信息

Demir Özgür, Öksüz Erol, Deniz Fatih Ersay, Demir Osman

机构信息

Department of Neurosurgery, Gaziosmanpaşa University, Tokat, Turkey.

Department of Biostatistics, Gaziosmanpaşa University, Tokat, Turkey.

出版信息

J Spine Surg. 2017 Dec;3(4):548-553. doi: 10.21037/jss.2017.09.05.

Abstract

BACKGROUND

Computed tomography (CT) with Hounsfield unit (HU) is being used with increasing frequency for determining bone density. Established correlations between HU and bone density have been shown in the literature. The aim of this retrospective study was to determine the bone density changes of the stabilized and adjacent segment vertebral bodies by comparing HU values before and after lumbar posterior stabilization.

METHODS

Sixteen patients who had similar diagnosis of lumbar spondylosis and stenosis were evaluated in this study. Same surgical procedures were performed to all of the patients with L2-3-4-5 transpedicular screw fixation, fusion and L3-4 total laminectomy. Bone mineral density measurements were obtained with clinical CT. Measurements were obtained from stabilized and adjacent segment vertebral bodies. Densities of vertebral bodies were evaluated with HU before the surgeries and approximately one year after the surgeries. The preoperative HU value of each vertebra was compared with postoperative HU value of the same vertebrae by using statistical analysis.

RESULTS

The HU values of vertebra in the stabilized and adjacent segments consistently decreased after the operations. There were significant differences between the preoperative HU values and the postoperative HU values of the all evaluated vertebral bodies in the stabilized and adjacent segments. Additionally first sacral vertebra HU values were found to be significantly higher than lumbar vertebra HU values in the preoperative group and postoperative group.

CONCLUSIONS

Decrease in the bone density of the adjacent segment vertebral bodies may be one of the major predisposing factors for adjacent segment disease (ASD).

摘要

背景

采用亨氏单位(HU)的计算机断层扫描(CT)用于测定骨密度的频率日益增加。文献中已表明HU与骨密度之间存在既定的相关性。这项回顾性研究的目的是通过比较腰椎后路稳定手术前后的HU值,确定稳定节段和相邻节段椎体的骨密度变化。

方法

本研究评估了16例诊断为腰椎病和腰椎管狭窄症的患者。所有患者均接受相同的手术操作,即L2 - 3 - 4 - 5经椎弓根螺钉固定、融合以及L3 - 4全椎板切除术。采用临床CT进行骨密度测量。测量稳定节段和相邻节段椎体。在手术前和手术后约一年,用HU评估椎体密度。通过统计分析比较每个椎体术前的HU值与术后同一椎体的HU值。

结果

手术后,稳定节段和相邻节段椎体的HU值持续下降。稳定节段和相邻节段所有评估椎体的术前HU值与术后HU值之间存在显著差异。此外,术前组和术后组中,第一骶椎的HU值均显著高于腰椎的HU值。

结论

相邻节段椎体骨密度降低可能是相邻节段疾病(ASD)的主要诱发因素之一。

相似文献

引用本文的文献

本文引用的文献

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验