Lavinsky Fabio, Benfica Camila Zanella, Castoldi Nédio, Cruz do Carmo Chaves Anne Elise, Mello Paulo Augusto de Arruda
Department of Ophthalmology, Paulista School of Medicine, São Paulo Hospital, Universidade Federal de São Paulo (UNIFESP), São Paulo, SP, Brazil.
Department of Ophthalmology, Universidade Federal do Rio Grande do Sul (UFRGS), Porto Alegre, RS, Brazil.
Clin Ophthalmol. 2018 Jan 23;12:215-225. doi: 10.2147/OPTH.S152772. eCollection 2018.
To evaluate the hypotenuse of the vertical optic nerve head cup (HVOC), measured using the length and depth of the cup obtained with enhanced depth imaging spectral-domain optic coherence tomography (SD-OCT), as a biomarker for glaucoma diagnosis.
This was a prospective cross-sectional study of patients with glaucoma and controls. SD-OCT was performed in all participants to assess average circumpapillary retinal nerve fiber layer (RNFL) thickness. A vertical B-scan of the optic nerve head (ONH) was obtained for HVOC measurement. The length and depth of the optic nerve cup formed the sides of a right triangle that were used to calculate the HVOC. Participants also underwent standard automated perimetry.
One hundred and fifty-six eyes were divided into three groups: mean deviation (MD) <-7 dB (60 eyes); MD ≥-7 dB (74 eyes); and healthy subjects (22 eyes). The mean (SD) HVOC in these groups was 1,419.8 (347.2) µm, 1,234.6 (258.8) µm, and 685.79 (315.4) µm (<0.01), respectively. In the secondary structure-function analysis, only discs with a vertical diameter of 1.51-2.00 mm were included (120 eyes). The HVOCs were divided into four percentile groups, with the following means: 940, 1,128, 1,390, and 1,662 µm. There was a significant difference in MD between percentile groups 1 and 3 (<0.03), 1 and 4 (<0.001), 2 and 3 (<0.02), and 2 and 4 (<0.001). RNFL thickness differed among all percentile groups (<0.001).
HVOC may provide an additional morphometric biomarker for the structural evaluation of ONH remodeling in glaucoma.
使用增强深度成像光谱域光学相干断层扫描(SD-OCT)获得的视杯长度和深度来测量垂直视神经乳头杯斜边(HVOC),评估其作为青光眼诊断生物标志物的价值。
这是一项针对青光眼患者和对照组的前瞻性横断面研究。对所有参与者进行SD-OCT检查,以评估平均视乳头周围视网膜神经纤维层(RNFL)厚度。获取视神经乳头(ONH)的垂直B扫描图像用于测量HVOC。视神经杯的长度和深度构成直角三角形的两条边,用于计算HVOC。参与者还接受了标准自动视野检查。
156只眼睛分为三组:平均偏差(MD)<-7 dB(60只眼睛);MD≥-7 dB(74只眼睛);以及健康受试者(22只眼睛)。这些组中的平均(标准差)HVOC分别为1419.8(347.2)μm、1234.6(258.8)μm和685.79(315.4)μm(<0.01)。在二级结构-功能分析中,仅纳入垂直直径为1.51-2.00 mm的视盘(120只眼睛)。HVOC被分为四个百分位数组,其平均值如下:940、1128、1390和1662μm。百分位数组1和3之间的MD存在显著差异(<0.03),1和4之间(<0.001),2和3之间(<0.02),以及2和4之间(<0.001)。所有百分位数组之间的RNFL厚度均有差异(<0.001)。
HVOC可能为青光眼视神经乳头重塑的结构评估提供一种额外的形态学生物标志物。