Suppr超能文献

在功率自行车上进行力量-速度测试对估计最佳峰值输出的可重复性。

Reproducibility of estimated optimal peak output using a force-velocity test on a cycle ergometer.

机构信息

Research Unity for Sport and Physical Activity (CIDAF, UID/DTP/04213/2016), University of Coimbra, Coimbra, Portugal.

Faculty of Sport Sciences and Physical Education, University of Coimbra, Coimbra, Portugal.

出版信息

PLoS One. 2018 Feb 23;13(2):e0193234. doi: 10.1371/journal.pone.0193234. eCollection 2018.

Abstract

The current study aimed to examine the reproducibility of estimated peak power and estimated pedal velocity in a multi-trial 10-s all-out cycling test among adult athletes (n = 22; aged 23.50±4.73 years). Stature, sitting height and body mass were measured. Leg length was estimated as stature minus sitting height. Body volume was obtained from air displacement plethysmography and was subsequently used to calculate body density. Fat mass and fat-free mass were derived. The short-term power outputs were assessed from the force-velocity test (FVT), using a friction-braked ergometer on two separated occasions. Differences between repeated measurements were examined with paired t-test and effect sizes calculated. No significant differences were found between session 1 (898 W, 142 rpm) and session 2 (906 W, 142 rpm). Test-retest procedure showed acceptable reliability for estimated peak power output [technical error of measurement (TEM) = 31.9 W; % coefficient of variation (CV) = 3.5; intra-class correlation coefficient (ICC) = 0.986] and pedal velocity (TEM = 5.4 rpm, %CV = 3.8, ICC = 0.924). The current study demonstrated a reasonable reproducibility of estimated peak power and pedal velocity outputs in non-elite male athletes and supports that a familiarization session including a complete FVT protocol is not required.

摘要

本研究旨在检验成年人运动员(n=22;年龄 23.50±4.73 岁)10 秒全力多试蹬踏测试中估计峰值功率和估计踏频的可重复性。测量身高、坐高和体重。腿长估计为身高减去坐高。通过空气置换体积描记法获得身体体积,并随后用于计算身体密度。得出脂肪质量和去脂体重。使用摩擦制动测功计在两个不同的场合进行力速测试(FVT)来评估短期功率输出。使用配对 t 检验检查重复测量之间的差异,并计算效应大小。在第一和第二测试中未发现显著差异(第 1 次测试 898 W,142 rpm;第 2 次测试 906 W,142 rpm)。测试-再测试程序表明,估计峰值功率输出的可靠性良好[测量技术误差(TEM)=31.9 W;%变异系数(CV)=3.5;组内相关系数(ICC)=0.986]和踏频(TEM=5.4 rpm,%CV=3.8,ICC=0.924)。本研究表明,非精英男性运动员的估计峰值功率和踏频输出具有合理的可重复性,并且支持不需要包括完整 FVT 协议的熟悉测试。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/2cc5/5825072/0c7361c25475/pone.0193234.g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验