Suppr超能文献

传导性听力损失模型中眼性和颈性前庭诱发肌源性电位的评估

Evaluation of ocular and cervical vestibular evoked myogenic potentials in a conductive hearing loss model.

作者信息

Han Peng, Zhang Rui, Chen Zichen, Gao Ying, Cheng Ying, Zhang Qing, Xu Min

机构信息

Department of Otorhinolaryngology-Head and Neck Surgery, Ear Institute, Second Affiliated Hospital, Xi'an Jiaotong University College of Medicine, Xi'an, 710004 China.

Department of Otorhinolaryngology-Head and Neck Surgery, Xi'an Children's Hospital, Xi'an, 710004 China.

出版信息

J Otol. 2016 Dec;11(4):192-197. doi: 10.1016/j.joto.2016.12.002. Epub 2017 Jan 4.

Abstract

OBJECTIVE

To investigate the effects of conductive hearing loss (CHL) on vestibular evoked myogenic potentials (VEMPs) using a simulated CHL model, and to provide the basis for future studies.

METHODS

Twenty-one healthy subjects were recruited in this study. We measured ocular VEMPs (oVEMPs) and cervical VEMPs (cVEMPs) in these subjects by air-conduction sound (ACS) stimulation. CHL was simulated later by blocking the right external auditory canal with a soundproof earplug to evaluate its impacts on VEMPs. Subjects' responses before simulated CHL served as the control, and were compared to their responses following simulated CHL.

RESULTS

oVEMPs following simulated CHL showed decreased response rate, elevated thresholds, attenuated amplitudes and prolonged N1 latencies compared with those before simulated CHL, and the differences were statistically significant. Similarly, cVEMPs following simulated CHL also showed decreased response rate, elevated thresholds and attenuated amplitudes, with prolonged P1 latencies compared with those before simulated CHL, although only differences in response rate, threshold and amplitude were significant.

CONCLUSIONS

Conductive hearing loss affects the response rate and other response parameters in oVEMPs and cVEMPs.

摘要

目的

使用模拟传导性听力损失(CHL)模型研究CHL对前庭诱发肌源性电位(VEMPs)的影响,为未来的研究提供依据。

方法

本研究招募了21名健康受试者。我们通过气导声音(ACS)刺激测量这些受试者的眼VEMPs(oVEMPs)和颈VEMPs(cVEMPs)。随后通过用隔音耳塞堵塞右外耳道来模拟CHL,以评估其对VEMPs的影响。模拟CHL前受试者的反应作为对照,并与模拟CHL后的反应进行比较。

结果

与模拟CHL前相比,模拟CHL后的oVEMPs显示反应率降低、阈值升高、振幅衰减和N1潜伏期延长,差异具有统计学意义。同样,模拟CHL后的cVEMPs也显示反应率降低、阈值升高和振幅衰减,与模拟CHL前相比P1潜伏期延长,尽管只有反应率、阈值和振幅的差异具有统计学意义。

结论

传导性听力损失会影响oVEMPs和cVEMPs的反应率及其他反应参数。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/c37e/6002615/3ada37574684/gr1.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验