PURPOSE

To evaluate the effect of a new-generation positional device, the sleep position trainer (SPT), in non-apneic position-dependent snorers.

METHODS

Non-apneic position-dependent snorers with an apnea-hypopnea index (AHI) < 5 events/h were included between February 2015 and September 2016. After inclusion, study subjects used the SPT at home for 6 weeks. The Snore Outcome Survey (SOS) was filled out by the subjects at baseline and after 6 weeks, and at the same time, the Spouse/Bed Partner Survey (SBPS) was filled out by their bed partners.

RESULTS

A total of 36 participants were included and 30 completed the study. SOS score improved significantly after 6 weeks from 35.0 ± 13.5 to 55.3 ± 18.6, p < 0.001. SBPS score also improved significantly after 6 weeks from 24.7 ± 16.0 versus 54.5 ± 25.2, p < 0.001. The severity of snoring assessed with a numeric visual analogue scale (VAS) by the bed partner decreased significantly from a median of 8.0 with an interquartile range (IQR) of [7.0-8.5] to 7.0 [3.8-8.0] after 6 weeks (p = 0.004).

CONCLUSIONS

Results of this study indicate that positional therapy with the SPT improved several snoring-related outcome measures in non-apneic position-dependent snorers. The results of this non-controlled study demonstrate that this SPT could be considered as an alternative therapeutic option to improve sleep-related health status of snorers and their bed partners.

摘要

目的

评估新一代定位设备——睡眠姿势训练器(SPT)对非呼吸暂停型体位性打鼾者的疗效。

方法

纳入2015年2月至2016年9月期间呼吸暂停低通气指数(AHI)<5次/小时的非呼吸暂停型体位性打鼾者。纳入后,研究对象在家中使用SPT 6周。研究对象在基线时和6周后填写打鼾结果调查问卷(SOS),同时,他们的同床伴侣填写配偶/同床伴侣调查问卷(SBPS)。

结果

共纳入36名参与者,30名完成了研究。6周后,SOS评分从35.0±13.5显著提高至55.3±18.6,p<0.001。6周后,SBPS评分也显著提高,从24.7±16.0提高至54.5±25.2,p<0.001。同床伴侣用数字视觉模拟量表(VAS)评估的打鼾严重程度在6周后从中位数8.0(四分位间距[IQR]为[7.0-8.5])显著降至7.0[3.8-8.0](p=0.004)。