Suppr超能文献

基于视觉和图像的 ICDAS 标准与微 CT 金标准在检测磨牙面龋损中的准确性比较。

Accuracy of visual and image-based ICDAS criteria compared with a micro-CT gold standard for caries detection on occlusal surfaces.

机构信息

Universidade Federal do Rio de Janeiro - UFRJ, School of Dentistry, Department of Pediatric Dentistry and Orthodontics, Rio de Janeiro, RJ, Brazil.

Universidade Federal do Rio de Janeiro - UFRJ, Laboratory for Nuclear Instrumentation, Rio de Janeiro, RJ, Brazil.

出版信息

Braz Oral Res. 2018 Jul 10;32:e60. doi: 10.1590/1807-3107bor-2018.vol32.0060.

Abstract

The aim of this study was to check the in vitro accuracy of ICDAS criteria on digital images compared to visual examination for the diagnosis of occlusal caries against a micro-CT gold standard. ICDAS was scored in 40 extracted permanent molars by means of visual inspection and stereomicroscopic images. Visual examinations were performed in duplicate and at a one-week interval by three different calibrated examiners. The analysis of digital images by ICDAS criteria was also performed in duplicate, 1 month after visual examinations. The detection methods were compared by means of sensitivity, specificity, area under the curve, predictive positive and negative values, and accuracy for two different thresholds (1- sound vs. carious teeth; 2- tooth requiring operative vs. non-operative treatment). Sensitivity and accuracy values for threshold 1 in the visual ICDAS and image-based ICDAS methods were high for sensitivity (0.93 and 0.97) and for accuracy (0.83 and 0.85), but low for specificity (0.55 for both methods). Specificity values for threshold 2 were 0.77 and 0.82, while sensitivity was 0.33 and 0.28 for each method. Spearman's rank correlation coefficient was 0.53 and 0.43 (p<0.05) for visual and image-based ICDAS compared to the gold standard scores. Both visual and image-based ICDAS scores were similar to each other in terms of diagnostic accuracy when compared to the micro-CT gold standard. Low specificity for the presence of caries and sensitivity for the detection of caries requiring operative treatment were found.

摘要

本研究旨在检查 ICDAS 标准在数字图像上的体外准确性,与微 CT 金标准相比,用于诊断咬合面龋。通过视觉检查和体视显微镜图像对 40 颗拔除的恒磨牙进行 ICDAS 评分。视觉检查由 3 名经过校准的不同检查者进行重复检查,并间隔一周进行。ICDAS 标准的数字图像分析也在视觉检查后 1 个月进行重复检查。通过敏感性、特异性、曲线下面积、阳性预测值和阴性预测值以及两个不同阈值(1-正常 vs. 龋坏牙;2-需要手术 vs. 非手术治疗的牙)的准确性比较检测方法。在视觉 ICDAS 和基于图像的 ICDAS 方法中,阈值 1 的敏感性和准确性值较高(敏感性为 0.93 和 0.97,准确性为 0.83 和 0.85),但特异性较低(两种方法均为 0.55)。阈值 2 的特异性值分别为 0.77 和 0.82,而敏感性分别为 0.33 和 0.28。与金标准评分相比,视觉和基于图像的 ICDAS 之间的 Spearman 等级相关系数分别为 0.53 和 0.43(p<0.05)。与微 CT 金标准相比,视觉和基于图像的 ICDAS 评分在诊断准确性方面相似。发现龋病存在的特异性较低,需要手术治疗的龋病检测的敏感性较低。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验