Suppr超能文献

支气管哮喘患者吸入装置的使用不当。巴西里约热内卢一项基于医院的横断面研究。

Incorrect use of inhalation devices among patients with bronchial asthma. A hospital-based cross-sectional study in Rio de Janeiro, Brazil.

作者信息

Pessôa Carlos Leonardo Carvalho, Mattos Maria Julia da Silva, Alho Artur Renato Moura, Fischmann Marianna Martini, Côrtes Ana Carolina Castro, Mendes Flávio de Oliveira, Haerdy Bruno Mendes, Brignol Sandra Mara Silva

机构信息

MD, MSc, PhD. Adjunct Professor, Department of Clinical Medicine, Universidade Federal Fluminense (UFF), Niterói (RJ), Brazil.

Medical Student, Universidade Federal Fluminense (UFF), Niterói (RJ), Brazil.

出版信息

Sao Paulo Med J. 2018 Jul-Aug;136(4):298-303. doi: 10.1590/1516-3180.2018.0050170418. Epub 2018 Aug 13.

Abstract

CONTEXT AND OBJECTIVE

Treatment of asthma implies inhalation of specific drugs to reach high concentrations in the respiratory tree and ensure low drug bioavailability and few adverse effects. This study aimed to evaluate the effectiveness of the inhalation technique among outpatients with asthma.

DESIGN AND SETTING

Tertiary-care hospital-based cross-sectional study in Rio de Janeiro.

METHODS

We evaluated inhalation practices in a convenience sample. A questionnaire was used to investigate sociodemographic data and assess disease control level, duration of use of the inhalation device, length of treatment and previous instructions provided by the prescribing physician. Patients demonstrated their inhalation technique using empty devices, and their technique was considered correct when all steps were appropriately performed or when errors did not interfere with the treatment outcome.

RESULTS

Among the 71 participants, 53 (74.7%) had been using the same inhaler device for at least two years and 41 (57.8%) had been under treatment for two years or more. Twelve (17.1%) said that they had been taught once and 57 (81.4%) at least twice, while one (1.4%) reported not having received any guidance regarding use of inhaler devices. Eighteen patients (25.3%) presented controlled asthma and 28 (39.5%) performed the inhalation technique correctly. Incorrect technique was associated with fewer evaluations of the inhalation technique (P =0.04) and uncontrolled asthma (P = 0.01).

CONCLUSIONS

Less than half of the sample performed the inhalation technique correctly. Incorrect inhalation technique was related to lower number of evaluations of the use of the inhalation device and uncontrolled asthma.

摘要

背景与目的

哮喘治疗需要吸入特定药物,以在呼吸道达到高浓度,并确保低药物生物利用度和较少的不良反应。本研究旨在评估哮喘门诊患者吸入技术的有效性。

设计与地点

在里约热内卢一家三级医疗医院进行的横断面研究。

方法

我们对一个便利样本的吸入操作进行了评估。使用问卷调查社会人口学数据,并评估疾病控制水平、吸入装置使用时长、治疗时间以及开处方医生之前提供的指导。患者使用空装置演示其吸入技术,当所有步骤都正确执行或错误不影响治疗效果时,其技术被认为是正确的。

结果

在71名参与者中,53名(74.7%)使用同一吸入装置至少两年,41名(57.8%)接受治疗两年或更长时间。12名(17.1%)表示他们只接受过一次教导,57名(81.4%)至少接受过两次教导,而1名(1.4%)报告未接受过任何关于吸入装置使用的指导。18名患者(25.3%)哮喘得到控制,28名(39.5%)正确执行了吸入技术。错误的技术与对吸入技术的评估较少(P = 0.04)和哮喘未得到控制(P = 0.01)相关。

结论

样本中不到一半的人正确执行了吸入技术。错误的吸入技术与吸入装置使用评估次数较少和哮喘未得到控制有关。

相似文献

1
Incorrect use of inhalation devices among patients with bronchial asthma. A hospital-based cross-sectional study in Rio de Janeiro, Brazil.
Sao Paulo Med J. 2018 Jul-Aug;136(4):298-303. doi: 10.1590/1516-3180.2018.0050170418. Epub 2018 Aug 13.
3
Factors related to the incorrect use of inhalers by asthma patients.
J Bras Pneumol. 2014 Jan-Feb;40(1):13-20. doi: 10.1590/S1806-37132014000100003.
6
Most frequent errors in inhalation technique of patients with asthma treated at a tertiary care hospital.
Einstein (Sao Paulo). 2019 May 2;17(2):eAO4397. doi: 10.31744/einstein_journal/2019AO4397.
7
Parameters affecting inhalation therapy adherence in elderly patients with chronic obstructive lung disease and asthma.
Geriatr Gerontol Int. 2017 Jun;17(6):999-1005. doi: 10.1111/ggi.12823. Epub 2016 Jul 18.
9
Determinants of an incorrect inhalation technique in patients with asthma or COPD.
Scand J Prim Health Care. 2001 Dec;19(4):255-60. doi: 10.1080/02813430152706792.

引用本文的文献

1
An evaluation of the use of inhalers in asthma and chronic obstructive pulmonary disease.
J Taibah Univ Med Sci. 2023 Jan 12;18(4):860-867. doi: 10.1016/j.jtumed.2023.01.001. eCollection 2023 Aug.
2
Predicting the Risk of Incorrect Inhalation Technique in Patients with Chronic Airway Diseases by a New Predictive Nomogram.
J Asthma Allergy. 2023 Jan 24;16:159-172. doi: 10.2147/JAA.S396694. eCollection 2023.

本文引用的文献

4
Systematic Review of Errors in Inhaler Use: Has Patient Technique Improved Over Time?
Chest. 2016 Aug;150(2):394-406. doi: 10.1016/j.chest.2016.03.041. Epub 2016 Apr 7.
5
Study of inhaler technique in asthma patients: differences between pediatric and adult patients.
J Bras Pneumol. 2015 Sep-Oct;41(5):405-9. doi: 10.1590/S1806-3713201500000014.
6
The role of questionnaires in the assessment of asthma control.
Pneumonol Alergol Pol. 2015;83(3):220-8. doi: 10.5603/PiAP.2015.0036.
7
Study of Proper use of Inhalational Devices by Bronchial Asthma or COPD Patients Attending a Tertiary Care Hospital.
J Clin Diagn Res. 2014 Oct;8(10):HC04-7. doi: 10.7860/JCDR/2014/9457.4976. Epub 2014 Oct 20.
10
Factors related to the incorrect use of inhalers by asthma patients.
J Bras Pneumol. 2014 Jan-Feb;40(1):13-20. doi: 10.1590/S1806-37132014000100003.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验