Ambrosio A M, Enria D A, Maiztegui J I
Intervirology. 1986;25(2):97-102. doi: 10.1159/000149662.
Detection of viremia was attempted by three different methods in 30 cases of Argentine hemorrhagic fever (AHF). Cocultivation of peripheral blood mononuclear cells (PBMC) with Vero cell monolayers was the most sensitive, detecting Junin virus (JV) in 96% of the cases. Inoculation of whole blood into suckling mice and on Vero cells rendered 53 and 46% of positive isolations, respectively. The results presented suggest that PBMC are infected with JV during the acute period of AHF. JV was isolated with decreasing frequency up to 3 days after treatment with immune plasma, but no virus was recovered from PBMC during early convalescence.
我们尝试用三种不同方法对30例阿根廷出血热(AHF)患者进行病毒血症检测。将外周血单个核细胞(PBMC)与Vero细胞单层进行共培养是最敏感的方法,在96%的病例中检测到胡宁病毒(JV)。将全血接种于乳鼠和Vero细胞,病毒分离阳性率分别为53%和46%。研究结果表明,在AHF急性期,PBMC会被JV感染。在使用免疫血浆治疗后3天内,JV分离频率逐渐降低,但在恢复期早期,PBMC中未再检测到病毒。