Suppr超能文献

办公室诊断性宫腔镜检查中的二氧化碳:一个悬而未决的问题。一项针对1982例手术的多中心随机试验。

Carbon dioxide in office diagnostic hysteroscopy: An open question. A multicenter randomized trial on 1982 procedures.

作者信息

Tagliaferri Valeria, Ricciardi Luigi, Ricciardi Raffaele, Pinto Lauro R, Lanzone Antonio, Scambia Giovanni, Guido Maurizio

机构信息

Department of Obstetrics and Gynaecology, Ente Ecclesiastico Ospedale Generale Regionale "F. Miulli", Acquaviva delle Fonti (BA), Italy; Department of Obstetrics and Gynaecology, Fondazione policlinico universitario A. Gemelli IRCCS- Università Cattolica del Sacro Cuore, Largo "A. Gemelli" 8, 00168, Roma, Italy.

Department of Obstetrics and Gynaecology, Fondazione Giovanni Paolo II, Campobasso, Italy.

出版信息

Eur J Obstet Gynecol Reprod Biol. 2019 Apr;235:97-101. doi: 10.1016/j.ejogrb.2018.09.041. Epub 2018 Sep 28.

Abstract

OBJECTIVE

to compare carbon dioxide and saline solution distension in diagnostic hysteroscopies with regards to patient discomfort and procedural time and in accordance with the instrument diameter (5 mm vs 3.5 mm). The secondary outcome was to evaluate the role of the patient age and the obstetrical history on perception of pain and procedural time.

STUDY DESIGN

This is a prospective multicenter randomized study including 1982 patients that underwent office diagnostic hysteroscopy in: Policlinico Abano Terme, Università Cattolica del Sacro Cuore in Rome and Ente Ecclesiastico Ospedale Generale Regionale "F. Miulli" in Acquaviva delle Fonti. They were firstly randomized according to distension medium and secondly according to instrument diameter. Pain perception after the procedure was assessed by VAS (Visual Analogue Scale) score and procedural time was registered. Mann-Whitney U test was used to compare data.

RESULTS

Lower pain score and procedural time were recorded with the employment of Carbon Dioxide (p < 001). Patient discomfort and procedural time were significantly influenced by the instrument diameter independent of the distension medium used, though in the subgroup where gas was employed VAS score after 1 min (VAS1) resulted lower compared to saline solution in both the traditional and mini-hysteroscopy procedures (p < 001).

CONCLUSION

Carbon dioxide and saline solution are both suitable distension media for outpatient diagnostic hysteroscopy; nonetheless, carbon dioxide confers advantages in terms of pain perception and procedural time.

摘要

目的

比较诊断性宫腔镜检查中二氧化碳扩张和生理盐水扩张在患者不适程度和操作时间方面的差异,并根据器械直径(5毫米对3.5毫米)进行比较。次要结果是评估患者年龄和产科病史对疼痛感知和操作时间的影响。

研究设计

这是一项前瞻性多中心随机研究,纳入了1982例在阿巴诺泰尔梅综合医院、罗马圣心天主教大学以及阿夸维瓦德丰蒂的“F. 缪利”地区教会综合医院接受门诊诊断性宫腔镜检查的患者。他们首先根据扩张介质进行随机分组,其次根据器械直径进行随机分组。术后通过视觉模拟评分法(VAS)评估疼痛感知,并记录操作时间。采用曼-惠特尼U检验比较数据。

结果

使用二氧化碳时记录到较低的疼痛评分和操作时间(p < 0.001)。患者不适程度和操作时间受器械直径显著影响,与所使用的扩张介质无关,不过在使用气体的亚组中,传统宫腔镜检查和微型宫腔镜检查中1分钟后的VAS评分(VAS1)均低于生理盐水组(p < 0.001)。

结论

二氧化碳和生理盐水都是适合门诊诊断性宫腔镜检查的扩张介质;然而,二氧化碳在疼痛感知和操作时间方面具有优势。