Potrebko Peter S, Keller Andrew, All Sean, Sejpal Samir, Pepe Julie, Saigal Kunal, Kandula Shravan, Sensakovic William F, Shridhar Ravi, Poleszczuk Jan, Biagioli Matthew
College of Medicine, University of Central Florida, Orlando, FL, USA.
Department of Physics, University of Central Florida, Orlando, FL, USA.
J Appl Clin Med Phys. 2018 Nov;19(6):159-165. doi: 10.1002/acm2.12471. Epub 2018 Oct 4.
The purpose of this work was to compare dose distributions between two radiosurgery modalities, single-isocenter volumetric modulated arc therapy (VMAT), and GammaKnife Perfexion (GK), in the treatment of a large number (≥7) of brain metastases. Twelve patients with 103 brain metastases were analyzed. The median number of targets per patient was 8 (range: 7-14). GK plans were compared to noncoplanar VMAT plans using both 6-MV flattening filter-free (FFF) and 10-MV FFF modes. Parameters analyzed included radiation therapy oncology group conformity index (CI), 12, 6, and 3 Gy isodose volumes (V12 Gy, V6 Gy, V3 Gy), mean and maximum hippocampal dose, and maximum skin dose. There were statistically significant differences in CI (2.5 ± 1.6 vs 1.6 ± 0.8 and 1.7 ± 0.9, P < 0.001, P < 0.001), V12 Gy (2.8 ± 6.1 cc vs 3.0 ± 5.2 cc and 3.1 ± 5.4 cc, P = 0.003, P < 0.001), and V3 Gy (323.0 ± 294.8 cc vs, 880.1 ± 369.1 cc and 937.9 ± vs 361.9 cc, P = 0.005, P = 0.001) between GK versus both 6-MV FFF and 10-MV FFF. No significant differences existed for maximum hippocampal or skin doses. In conclusion, highly optimized VMAT produced improved conformity at the expense of a higher V12 Gy and V3 Gy volume when compared with highly optimized GK.
本研究的目的是比较两种放射外科治疗方式,即单等中心容积调强弧形放疗(VMAT)和伽玛刀Perfexion(GK),在治疗大量(≥7个)脑转移瘤时的剂量分布。分析了12例患有103个脑转移瘤的患者。每位患者的靶区中位数为8个(范围:7 - 14个)。将GK计划与使用6兆伏无均整器(FFF)和10兆伏FFF模式的非共面VMAT计划进行比较。分析的参数包括放射肿瘤学组适形指数(CI)、12、6和3 Gy等剂量体积(V12 Gy、V6 Gy、V3 Gy)、海马平均剂量和最大剂量以及最大皮肤剂量。GK与6兆伏FFF和10兆伏FFF相比,在CI(2.5±1.6对1.6±0.8和1.7±0.9,P<0.001,P<0.001)、V12 Gy(2.8±6.1立方厘米对3.0±5.2立方厘米和3.1±5.4立方厘米,P = 0.003,P<0.001)和V3 Gy(323.0±294.8立方厘米对880.1±369.1立方厘米和937.9±对361.9立方厘米,P = 0.005,P = 0.001)方面存在统计学显著差异。海马或皮肤最大剂量无显著差异。总之,与高度优化的GK相比,高度优化的VMAT以更高的V12 Gy和V3 Gy体积为代价提高了适形性。