Broux B, De Clercq D, Vera L, Ven S, Deprez P, Decloedt A, van Loon G
Equine Cardioteam, Department of Large Animal Internal Medicine, Faculty of Veterinary Medicine, Ghent University, Salisburylaan 133, 9820, Merelbeke, Belgium.
BMC Vet Res. 2018 Oct 25;14(1):320. doi: 10.1186/s12917-018-1650-6.
Heart rate variability (HRV) parameters, and especially RMSSD (root mean squared successive differences in RR interval), could distinguish atrial fibrillation (AF) from sinus rhythm(SR) in horses, as was demonstrated in a previous study. If heart rate monitors (HRM) automatically calculating RMSSD could also distinguish AF from SR, they would be useful for the monitoring of AF recurrence. The objective of the study was to assess whether RMSSD values obtained from a HRM can differentiate AF from SR in horses. Furthermore, the impact of artifact correction algorithms, integrated in the analyses software for HRV analyses was evaluated. Fourteen horses presented for AF treatment were simultaneously equipped with a HRM and an electrocardiogram (ECG). A two-minute recording at rest, walk and trot, before and after cardioversion, was obtained. RR intervals used were those determined automatically by the HRM and by the equine ECG analysis software, and those obtained after manual correction of QRS detection within the ECG software. RMSSD was calculated by the HRM software and by dedicated HRV software, using six different artifact filters. Statistical analysis was performed using the Wilcoxon signed-rank test and receiver operating curves.
The HRM, which applies a low level filter, produced high area under the curve (AUC) (> 0.9) and cut off values with high sensitivity and specificity. Similar results were obtained for the ECG, when low level artifact filtering was applied. When no artifact correction was used during trotting, an important decrease in AUC (0.75) occurred.
In horses treated for AF, HRMs with automatic RMSSD calculations distinguish between AF and SR. Such devices might be a useful aid to monitor for AF recurrence in horses.
心率变异性(HRV)参数,尤其是RR间期的均方根连续差值(RMSSD),能够区分马的房颤(AF)和窦性心律(SR),这在之前的一项研究中得到了证实。如果心率监测器(HRM)能够自动计算RMSSD并区分AF和SR,那么它们将有助于监测AF复发。本研究的目的是评估从HRM获得的RMSSD值能否区分马的AF和SR。此外,还评估了HRV分析软件中集成的伪差校正算法的影响。14匹因AF接受治疗的马同时配备了HRM和心电图(ECG)。在心脏复律前后,分别在静息、行走和小跑状态下进行了两分钟的记录。使用的RR间期是由HRM和马用ECG分析软件自动确定的,以及在ECG软件中手动校正QRS检测后获得的。RMSSD由HRM软件和专用的HRV软件使用六种不同的伪差滤波器计算得出。使用Wilcoxon符号秩检验和受试者工作特征曲线进行统计分析。
应用低水平滤波器的HRM产生了较高的曲线下面积(AUC)(>0.9)以及具有高灵敏度和特异性的截断值。当应用低水平伪差滤波时,ECG也获得了类似的结果。在小跑过程中不使用伪差校正时,AUC出现了显著下降(0.75)。
在接受AF治疗的马中,能够自动计算RMSSD的HRM可以区分AF和SR。此类设备可能有助于监测马的AF复发。