Na Eui-Ri, Aljawad Hussein, Lee Kyung-Min, Hwang Hyeon-Shik
Department of Periodontology, School of Dentistry, Chonnam National University, Gwangju, Korea.
Department of Orthodontics, School of Dentistry, Chonnam National University, Gwangju, Korea.
Korean J Orthod. 2019 Jan;49(1):41-48. doi: 10.4041/kjod.2019.49.1.41. Epub 2018 Dec 19.
This study aimed to compare landmark identification errors in anteroposterior (AP) and posteroanterior (PA) cephalograms generated from cone-beam computed tomography (CBCT) scan data in order to examine the feasibility of using AP cephalograms in clinical settings.
AP and PA cephalograms were generated from CBCT scans obtained from 25 adults. Four experienced and four inexperienced examiners were selected depending on their experience levels in analyzing frontal cephalograms. They identified six cephalometric landmarks on AP and PA cephalograms. The errors incurred in positioning the cephalometric landmarks on the AP and PA cephalograms were calculated by using the straight-line distance and the horizontal and vertical components as parameters.
Comparison of the landmark identification errors in CBCT-generated frontal cephalograms revealed that landmark-dependent differences were greater than experience- or projection-dependent differences. Comparisons of landmark identification errors in the horizontal and vertical directions revealed larger errors in identification of the crista galli and anterior nasal spine in the vertical direction and the menton in the horizontal direction, in comparison with the other landmarks. Comparison of landmark identification errors between the AP and PA projections in CBCT-generated images revealed a slightly higher error rate in the AP projections, with no inter-examiner differences. Statistical testing of the differences in landmark identification errors between AP and PA cephalograms showed no statistically significant differences for all landmarks.
The reproducibility of CBCT-generated AP cephalograms is comparable to that of PA cephalograms; therefore, AP cephalograms can be generated reliably from CBCT scan data in clinical settings.
本研究旨在比较由锥形束计算机断层扫描(CBCT)扫描数据生成的前后位(AP)和后前位(PA)头颅侧位片上标志点识别误差,以检验在临床环境中使用AP头颅侧位片的可行性。
从25名成年人的CBCT扫描中生成AP和PA头颅侧位片。根据他们在分析额部头颅侧位片方面的经验水平,挑选了四名经验丰富的和四名经验不足的检查者。他们在AP和PA头颅侧位片上识别六个头影测量标志点。以直线距离以及水平和垂直分量为参数,计算在AP和PA头颅侧位片上定位头影测量标志点时产生的误差。
CBCT生成的额部头颅侧位片中标志点识别误差的比较显示,标志点相关差异大于经验或投影相关差异。水平和垂直方向上标志点识别误差的比较显示,与其他标志点相比,在垂直方向上鸡冠和前鼻棘的识别误差较大,在水平方向上颏下点的识别误差较大。CBCT生成图像中AP和PA投影之间标志点识别误差的比较显示,AP投影中的误差率略高,检查者之间无差异。对AP和PA头颅侧位片之间标志点识别误差差异的统计检验显示,所有标志点均无统计学显著差异。
CBCT生成的AP头颅侧位片的可重复性与PA头颅侧位片相当;因此,在临床环境中可以从CBCT扫描数据可靠地生成AP头颅侧位片。