Suppr超能文献

比较扫频源和谱域光学相干断层扫描在视网膜疾病中测量视网膜内层厚度的重复性。

Comparison of repeatability of swept-source and spectral-domain optical coherence tomography for measuring inner retinal thickness in retinal disease.

机构信息

Department of Ophthalmology, Hanyang University College of Medicine, Seoul, Korea.

Department of Anesthesiology and Pain Medicine, Hanyang University College of Medicine, Seoul, Korea.

出版信息

PLoS One. 2019 Jan 16;14(1):e0210729. doi: 10.1371/journal.pone.0210729. eCollection 2019.

Abstract

PURPOSE

To compare repeatability between SS-OCT and SD-OCT for measurement of macular, macular retinal nerve fiber (mRNFL), and ganglion cell-inner plexiform layer (GC-IPL) thickness in various retinal diseases.

METHODS

One hundred and fourteen eyes of 114 subjects were investigated. Seventy-eight eyes with retinal disease and 36 normal eyes underwent two consecutive measurements of macular, mRNFL, and GC-IPL thickness using SS-OCT and SD-OCT. The data were obtained using the Early Treatment Diabetic Retinopathy Study (ETDRS) protocol. The eyes with retinal diseases were divided into three subgroups according to central macular thickness (CMT) for analysis. The intraclass correlation coefficient (ICC) was calculated to determine the repeatability of OCT device.

RESULTS

In normal eyes, both OCT devices showed excellent repeatability of macula, mRNFL, and GC-IPL thickness measurements with high ICCs in all ETDRS subfields. In eyes with retinal disease, although SS-OCT showed better repeatability for inner retinal thickness measurements than SD-OCT, the overall ICCs were lower than those in normal eyes. In subgroup analysis, the ICCs in the low CMT group were lower than those in the normal and high CMT groups, particularly when using SD-OCT.

CONCLUSIONS

Both OCT devices had comparable repeatability for retinal thickness measurement in normal eyes and eyes with retinal disease. However, the possibility of measurement error should be considered in eyes with a thin and atrophic retina.

摘要

目的

比较 SS-OCT 和 SD-OCT 测量各种视网膜疾病的黄斑、视网膜神经纤维层(mRNFL)和神经节细胞-内丛状层(GC-IPL)厚度的重复性。

方法

对 114 例 114 只眼进行研究。78 只视网膜疾病眼和 36 只正常眼分别用 SS-OCT 和 SD-OCT 进行两次连续黄斑、mRNFL 和 GC-IPL 厚度测量。采用早期糖尿病视网膜病变研究(ETDRS)方案获得数据。根据中央黄斑厚度(CMT)将眼病眼分为三组进行分析。计算组内相关系数(ICC)以确定 OCT 设备的重复性。

结果

在正常眼中,两种 OCT 设备对黄斑、mRNFL 和 GC-IPL 厚度的测量均具有出色的重复性,所有 ETDRS 子区域的 ICC 均较高。在视网膜疾病眼中,尽管 SS-OCT 对视网膜内层厚度的测量重复性优于 SD-OCT,但总体 ICC 低于正常眼。在亚组分析中,低 CMT 组的 ICC 低于正常和高 CMT 组,尤其是使用 SD-OCT 时。

结论

在正常眼和视网膜疾病眼中,两种 OCT 设备对视网膜厚度的测量均具有可比性的重复性。然而,在视网膜薄且萎缩的眼中,应考虑测量误差的可能性。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/dbcb/6334919/07716212b379/pone.0210729.g001.jpg

相似文献

5
Repeatability of ganglion cell-inner plexiform layer thickness measurements using spectral-domain OCT in branch retinal vein occlusion.
Graefes Arch Clin Exp Ophthalmol. 2017 Sep;255(9):1727-1735. doi: 10.1007/s00417-017-3710-1. Epub 2017 Jun 11.
6
Diagnostic ability of macular nerve fiber layer thickness measured by swept-source optical coherence tomography in preperimetric glaucoma.
J Chin Med Assoc. 2024 Jul 1;87(7):722-727. doi: 10.1097/JCMA.0000000000001112. Epub 2024 May 21.

引用本文的文献

1
Premacular membranes and glaucoma: a review of clinical and therapeutic considerations.
Graefes Arch Clin Exp Ophthalmol. 2025 Mar 13. doi: 10.1007/s00417-025-06796-8.
2
Neuroretinal Alterations in Schizophrenia and Bipolar Disorder: An Updated Meta-analysis.
Schizophr Bull. 2024 Aug 27;50(5):1067-1082. doi: 10.1093/schbul/sbae102.
3
Decrease Retinal Thickness in Patients with Chronic Migraine Evaluated by Optical Coherence Tomography.
Diagnostics (Basel). 2022 Dec 20;13(1):5. doi: 10.3390/diagnostics13010005.
4
Association of Inner Retinal Thickness with Prevalent Dementia and Brain Atrophy in a General Older Population: The Hisayama Study.
Ophthalmol Sci. 2022 Apr 19;2(2):100157. doi: 10.1016/j.xops.2022.100157. eCollection 2022 Jun.
6
Impact of Epiretinal Membrane on Optical Coherence Tomography Tools Used for Monitoring Glaucoma.
Diagnostics (Basel). 2021 Nov 26;11(12):2203. doi: 10.3390/diagnostics11122203.

本文引用的文献

4
In vivo evaluation of retinal ganglion cells degeneration in eyes with branch retinal vein occlusion.
Br J Ophthalmol. 2016 Nov;100(11):1506-1510. doi: 10.1136/bjophthalmol-2015-308106. Epub 2016 Feb 22.
6
Comparison of Retinal Thickness Measurements between the Topcon Algorithm and a Graph-Based Algorithm in Normal and Glaucoma Eyes.
PLoS One. 2015 Jun 4;10(6):e0128925. doi: 10.1371/journal.pone.0128925. eCollection 2015.
7
Ganglion Cell-Inner Plexiform Layer Thickness in Retinal Diseases: Repeatability Study of Spectral-Domain Optical Coherence Tomography.
Am J Ophthalmol. 2015 Aug;160(2):283-289.e1. doi: 10.1016/j.ajo.2015.05.015. Epub 2015 May 21.
8
Comparison of retinal thicknesses measured using swept-source and spectral-domain optical coherence tomography devices.
Ophthalmic Surg Lasers Imaging Retina. 2015 Feb;46(2):172-9. doi: 10.3928/23258160-20150213-23.

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验