Sensors (Basel). 2019 Jan 17;19(2):359. doi: 10.3390/s19020359.
In this paper, we discuss the potential use of four transistor active pixel sensor (4T-APS) as a video monitor at a nuclear accident site with a high level of γ radiation. The resistance and radiation responses to γ radiation were investigated by radiation experiments using Cs and Co γ-ray sources. The radiation resistance of 4T-APS was studied by testing the mean and the maximum dark current of the sensors after irradiation. A random spatial distribution of radiation response events was observed upon analyzing these events on the video images in a given time during irradiation. The background dependence of the 4T-APS was also studied by comparing the grayscale incremental value of the images with different color and grayscale backgrounds: the radiation response events were obvious on the images with a background having a smaller grayscale value or a deeper color. Finally, the color saturation and resolution of the images were tested using a vector oscilloscope and a test card. When the total ionizing dose was less than or equal to the damage threshold, no significant performance deterioration of 4T-APS was observed in an environment with sufficient light.
在本文中,我们讨论了将四晶体管有源像素传感器(4T-APS)用作γ辐射水平很高的核事故现场视频监视器的潜在用途。通过使用 Cs 和 Co γ射线源进行辐射实验,研究了 4T-APS 的电阻和辐射对γ辐射的响应。通过测试传感器在辐照后的平均和最大暗电流,研究了 4T-APS 的辐射抗性。在辐照过程中,对给定时间内视频图像上的这些事件进行分析,观察到辐射响应事件的随机空间分布。通过比较不同颜色和灰度背景图像的灰度增量值,还研究了 4T-APS 的背景依赖性:在灰度值较小或颜色较深的背景图像上,辐射响应事件明显。最后,使用矢量示波器和测试卡测试了图像的色彩饱和度和分辨率。当总离子剂量小于或等于损伤阈值时,在光照充足的环境中,4T-APS 的性能没有明显恶化。