Abstract

Dual energy X-ray absorptiometry (DXA) has become the most common method for measuring bone mineral density (BMD) of small animals in metabolic bone disease research, and errors should be minimized in all procedures involved in research studies in order to increase the accuracy of the study results. DXA is simpler and rapid compared to micro-computed tomography for quantitative analysis of change in trabecular bone of test subject. In human research, measuring BMD is widely used; postoperative evaluation on orthopedic surgery, evaluation of osteoporosis medication in menopause and many other areas of study. For the study, the inspector should be trained by the equipment manufacturer regarding the utilization and analysis of the equipment and regular phantom testing should be conducted to ensure the stability of the equipment, and precision tests should be conducted to analyze the positioning and data analysis. They should also be familiar with the clinical trials and conduct studies based on the approval of the Institutional Review Board. In the absolute BMD measurement of the human body, it is necessary to apply and compare the position and condition, rotation degree, region of interest, and area of the scan in the follow-up test. In the case of small animals, animal selection, measurement and equipment should be modeled to match the research. Therefore, we would like to provide information for researchers to minimize the errors, effective data management and accurate data presentation. This article reviews the process of DXA measurement for research purpose including plan for DXA examination, BMD measurement in a human body study and small animal studies.

摘要

双能X线吸收法(DXA)已成为代谢性骨病研究中测量小动物骨密度(BMD)最常用的方法,在研究的所有程序中都应尽量减少误差,以提高研究结果的准确性。与微计算机断层扫描相比,DXA在定量分析受试对象小梁骨变化方面更简单、快速。在人体研究中,测量骨密度被广泛应用;用于骨科手术后评估、绝经后骨质疏松症药物评估以及许多其他研究领域。对于该研究,检查人员应接受设备制造商关于设备使用和分析的培训,并应定期进行体模测试以确保设备稳定性,还应进行精度测试以分析定位和数据分析。他们还应熟悉临床试验,并在机构审查委员会批准的基础上进行研究。在人体绝对骨密度测量中,在后续测试中有必要应用并比较扫描的位置和条件、旋转角度、感兴趣区域和面积。对于小动物,动物选择、测量和设备应进行建模以匹配研究。因此,我们希望为研究人员提供信息,以尽量减少误差、进行有效的数据管理和准确的数据呈现。本文回顾了用于研究目的的DXA测量过程,包括DXA检查计划、人体研究和小动物研究中的骨密度测量。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/03c7/6362959/f22bdb31925c/gr1.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验