Suppr超能文献

使用传统车针、铒激光(Er:YAG)和铒铬钇钪镓石榴石激光(Er,Cr:YSGG)进行窝洞预备后根管充填牙的抗折性

Fracture resistance of root-filled teeth after cavity preparation with conventional burs, Er: YAG and Er,Cr: YSGG lasers.

作者信息

Aydın Uğur, Aksoy Fatih, Tosun Samet

机构信息

Department of Endodontics, Gaziantep University Faculty of Dentistry, Gaziantep, Turkey.

Department of Endodontics, Adıyaman University Faculty of Dentistry, Adıyaman, Turkey.

出版信息

Eur Oral Res. 2018 May;52(2):59-63. doi: 10.26650/eor.2018.442. Epub 2018 May 1.

Abstract

PURPOSE

The aim of the present study is to compare the fracture resistance of teeth after access cavity preparation with conventional rotary burs, Erbium-doped yttrium aluminum garnet laser (Er:YAG) and Erbium, cromium: yttrium scandium gallium garnet laser (Er,Cr:YSGG) lasers.

MATERIALS AND METHODS

Fifty five intact mandibular molars were divided into 3 negative groups (groups 1, 2, 3; n=5 for each), 3 study groups (groups 4, 5, 6; n=10 for each) and 1 positive control group (intact teeth; n=10). Access cavities of groups 1, 2 and 3 were prepared with conventional burs, Er:YAG laser and Er,Cr:YSGG laser respectively. After root canal obturation, their coronal portions were left non-restored. Access cavities of groups 4, 5 and 6 were prepared by using the same equipment but their coronal portions were restored with composite resinafter root canal obturation. Following thermocycling, fracture strength was evaluated with a Universal Testing Machine. Mean force at which each sample is fractured was recorded in Newton unit and statistically analyzed.

RESULTS

Fracture resistance of group 7 (intact teeth) was significantly higher than all other groups (p<0.001). Differences among the fracture resistance values of groups 4, 5 and 6 were not significantly different but they were significantly higher than those of groups 1, 2 and 3 (p<0.001). No significant difference was found between Groups 1, 2 and 3.

CONCLUSION

Preparing access cavities with either laser or bur has no effect on the fracture resistance of teeth with root canal treatment.

摘要

目的

本研究旨在比较使用传统旋转车针、掺铒钇铝石榴石激光(Er:YAG)和铒铬:钇钪镓石榴石激光(Er,Cr:YSGG)制备开髓洞形后牙齿的抗折性。

材料与方法

55颗完整的下颌磨牙分为3个阴性组(1组、2组、3组;每组n = 5)、3个研究组(4组、5组、6组;每组n = 10)和1个阳性对照组(完整牙齿;n = 10)。1组、2组和3组的开髓洞形分别用传统车针、Er:YAG激光和Er,Cr:YSGG激光制备。根管充填后,其冠部不做修复。4组、5组和6组用相同设备制备开髓洞形,但根管充填后其冠部用复合树脂修复。经过热循环后,用万能试验机评估抗折强度。记录每个样本折断时的平均力,单位为牛顿,并进行统计学分析。

结果

7组(完整牙齿)的抗折性显著高于所有其他组(p < 0.001)。4组、5组和6组抗折性值之间的差异无统计学意义,但显著高于1组、2组和3组(p < 0.001)。1组、2组和3组之间未发现显著差异。

结论

使用激光或车针制备开髓洞形对根管治疗后牙齿的抗折性没有影响。

相似文献

8
Apical microleakage of root-end cavities prepared by Er, Cr: YSGG laser.根尖微渗漏的根面窝洞预备 Er, Cr: YSGG 激光。
Lasers Med Sci. 2010 Jan;25(1):145-50. doi: 10.1007/s10103-009-0661-8. Epub 2009 Mar 11.

本文引用的文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验