1 Hearing Sciences-Scottish Section, Division of Clinical Neuroscience, University of Nottingham, Glasgow, UK.
2 School of Medicine, Dentistry, and Nursing, College of Medical, Veterinary, and Life Sciences, University of Glasgow, Glasgow, UK.
Trends Hear. 2019 Jan-Dec;23:2331216518820220. doi: 10.1177/2331216518820220.
Frequency-dependent gain adjustments are routine in hearing-aid fittings, whether in matching to real-ear targets or fine-tuning to patient feedback. Patient feedback may be unreliable and fittings inefficient if adjustments are not discriminable. To examine what gain adjustments are discriminable, we measured the just-noticeable differences (JNDs) for level increments in speech-shaped noises processed with prescription gains. JNDs were measured in the better ears of 38 participants with hearing impairment using a fixed-level, same-different task. JNDs were measured for increments at six individual frequency-bands: a 0.25-kHz low-pass band; octave-wide bands at 0.5, 1, 2, and 4 kHz; and a 6-kHz high-pass band. JNDs for broadband increments were also measured. JNDs were estimated at d' of 1 for a minimally discriminable increment in optimal laboratory conditions. The JND for frequency-band increments was 2.8 dB excluding the 0.25-kHz low-pass band, for which the JND was 4.5 dB. The JND for broadband increments was 1.5 dB. Participants' median frequency-band and broadband JNDs were positively correlated. JNDs were mostly independent of age, pure-tone thresholds, and cognitive score. In consideration of self-fitting adjustments in noisier conditions, JNDs were additionally estimated at a more sensitive d' of 2. These JNDs were 6 dB for bands below 1 kHz, and 5 dB for bands at and above 1 kHz. Overall, the results suggest noticeable fine-tuning adjustments of 3 dB and self-fitting adjustments of 5 dB.
频率依赖增益调整是助听器验配中的常规操作,无论是匹配真耳目标还是根据患者反馈进行微调。如果调整不可区分,则患者反馈可能不可靠,且助听器适配效率低下。为了研究可区分的增益调整,我们测量了经处方增益处理的语音噪声的电平增量的可察觉差(JND)。使用固定电平的相同-不同任务,在 38 名听力障碍参与者的较好耳中测量了 JND。在六个单独的频率带中测量了增量:0.25 kHz 的低通带;0.5、1、2 和 4 kHz 的倍频程宽带;以及 6 kHz 的高通带。还测量了宽带增量的 JND。在最佳实验室条件下,估计最小可区分增量的 JND 为 d' 1。不包括 0.25 kHz 低通带的频率带增量 JND 为 2.8 dB,0.25 kHz 低通带的 JND 为 4.5 dB。宽带增量的 JND 为 1.5 dB。参与者的中频带和宽带 JND 呈正相关。JND 主要与年龄、纯音阈值和认知评分无关。考虑到在更嘈杂的条件下进行自我适配调整,还在更敏感的 d' 2 下估算了 JND。这些 JND 对于低于 1 kHz 的频段为 6 dB,对于 1 kHz 及以上频段为 5 dB。总的来说,结果表明可进行 3 dB 的明显微调调整和 5 dB 的自我适配调整。