Lee Jinhee, Asano Shotaro, Inoue Tatsuya, Fujino Yuri, Matsuura Masato, Kitamoto Kodai, Hashimoto Yohei, Ogawa Asako, Yanagisawa Mieko, Azuma Keiko, Murata Hiroshi, Obata Ryo, Asaoka Ryo
Department of Ophthalmology, The University of Tokyo, Graduate School of Medicine, Tokyo, Japan.
Department of Ophthalmology, The University of Tokyo, Graduate School of Medicine, Tokyo, Japan.
Ophthalmol Retina. 2018 Oct;2(10):1062-1070. doi: 10.1016/j.oret.2018.03.007. Epub 2018 May 18.
To investigate the relationship between visual field (VF) loss and the rings of the ellipsoid zone (EZ) and autofluorescence (AF) in patients with retinitis pigmentosa (RP).
Cross-sectional study.
A total of 28 eyes of 15 patients with a clinical diagnosis of RP.
The VF was measured at a 1-degree interval on the horizontal or vertical lines, within the central 10 degrees from fixation, using MP-3 microperimetry (Nidek Co. Ltd., Aichi, Japan), and the sensitivity deviation from the normative database was calculated. OCT was performed, and the EZ was identified. Fundus AF was also measured, and the AF ring was identified. The VF test points were categorized according to their relationship with the EZ line and AF ring. The relationship between mean retinal sensitivity deviations on both the horizontal and vertical lines and the diameters of the EZ line and the AF ring in the corresponding directions was analyzed. The relationship between visual sensitivity deviation and the locations against EZ line and AF rings was also investigated.
The relationship between the visual sensitivity deviation and the locations against EZ line and AF rings.
The diameter of the AF ring had a significantly stronger relationship with mean retinal sensitivity deviation compared with the diameter of the EZ line in both the horizontal and vertical directions. Test point location inside/on/outside the AF ring was significantly related to retinal sensitivity deviation independent of the location inside/outside the EZ line (P < 0.001, linear mixed model).
Visual sensitivity damage is significantly associated with the EZ lines and AF rings. The development of the AF ring is related to the decrease of visual function independent of and stronger than the EZ line.
研究视网膜色素变性(RP)患者的视野(VF)缺损与椭圆体带(EZ)环及自身荧光(AF)之间的关系。
横断面研究。
15例临床诊断为RP的患者共28只眼。
使用MP-3微视野计(日本爱知县尼德克有限公司)在距注视点中心10度范围内的水平或垂直线上以1度间隔测量VF,并计算与正常数据库的敏感度偏差。进行光学相干断层扫描(OCT)并识别EZ。还测量了眼底AF并识别AF环。根据VF测试点与EZ线和AF环的关系进行分类。分析水平和垂直线上的平均视网膜敏感度偏差与相应方向上EZ线和AF环直径之间的关系。还研究了视觉敏感度偏差与相对于EZ线和AF环位置的关系。
视觉敏感度偏差与相对于EZ线和AF环位置的关系。
在水平和垂直方向上,AF环直径与平均视网膜敏感度偏差的关系均比EZ线直径与平均视网膜敏感度偏差的关系显著更强。AF环内/上/外的测试点位置与视网膜敏感度偏差显著相关,且与EZ线内/外的位置无关(P<0.001,线性混合模型)。
视觉敏感度损害与EZ线和AF环显著相关。AF环发展与视觉功能下降有关,且独立于EZ线且比EZ线更密切相关。