Abstract

Feasibility study of accurate three lead ECG recording (Einthoven I, II and III) using an Apple Watch Series 4. : In 50 healthy subjects (18 male; age: 40 ± 12 years) without known cardiac disorders, a 12-lead ECG and three bipolar ECGs, corresponding to Einthoven leads I, II and III were recorded using an Apple Watch Series 4. Einthoven I was recorded with the watch on the left wrist and the right index finger on the crown, Einthoven II with the watch on the left lower abdomen and the right index finger on the crown, Einthoven III with the watch on the left lower abdomen and the left index finger on the crown. Four experienced cardiologists were independently asked to assign the watch ECGs to Einthoven leads from 12-lead ECG for each subject. All watch ECGs showed an adequate signal quality with 134 ECGs of good (89%) and 16 of moderate signal quality (11%). Ninety-one percent of all watch ECGs were assigned correctly to corresponding leads from 12-lead ECG. Thirty-nine subjects (78%) were assigned correctly by all cardiologists. All assignment errors occurred in patients with similar morphologies and amplitudes in at least two of the three recorded leads. Erroneous assignment of all watch ECGs to leads from standard ECG occurred in no patient. Recording of Einthoven leads I-III by a smartwatch is accurate and highly comparable to standard ECG. This might contribute to an earlier detection of cardiac disorders, which are associated with repolarization abnormalities or arrhythmias.

摘要

使用 Apple Watch Series 4 进行准确的三导联心电图记录(Einthoven I、II 和 III)的可行性研究:在 50 名无已知心脏疾病的健康受试者(18 名男性;年龄:40 ± 12 岁)中,使用 Apple Watch Series 4 记录了 12 导联心电图和三个双极导联心电图,分别对应于 Einthoven 导联 I、II 和 III。Einthoven I 通过将手表戴在左手腕和右手中指放在表冠上记录,Einthoven II 通过将手表戴在左下腹和右手中指放在表冠上记录,Einthoven III 通过将手表戴在左下腹和左手中指放在表冠上记录。四名经验丰富的心脏病专家分别被要求根据每个受试者的 12 导联心电图将手表心电图分配到 Einthoven 导联。所有手表心电图均显示出良好的信号质量,134 个心电图信号质量良好(89%),16 个心电图信号质量中等(11%)。91%的手表心电图能够正确地分配到 12 导联心电图的相应导联上。所有心脏病专家均正确分配了 39 名受试者(78%)的心电图。所有分配错误均发生在至少两个记录导联中具有相似形态和幅度的患者中。在没有患者中出现所有手表心电图错误地分配到标准心电图导联的情况。智能手表记录 Einthoven I-III 导联的准确性和与标准心电图的高度可比性。这可能有助于更早地发现与复极异常或心律失常相关的心脏疾病。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/1cc0/6651039/c05f81754df1/sensors-19-02894-g001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验