Suppr超能文献

对0.016英寸镍钛合金和不锈钢正畸弓丝在自锁金属托槽和美观托槽中逐渐弯曲时产生的力的评估。

Evaluation of the force generated by gradual deflection of 0.016-inch NiTi and stainless steel orthodontic wires in self-ligating metallic and esthetic brackets.

作者信息

Francisconi Manoela-Fávaro, Janson Guilherme, Henriques José-Fernando-Castanha, Freitas Karina-Maria-Salvatore, Francisconi Paulo-Afonso-Silveira

机构信息

D.D.S., M.Sc. Orthodontic Graduate Student. Department of Orthodontics. Bauru Dental School. University of São Paulo, Bauru, Brazil.

D.D.S., M.Sc., Ph.D. Professor and Head. Department of Orthodontics. Bauru Dental School, University of São Paulo, Bauru, Brazil.

出版信息

J Clin Exp Dent. 2019 May 1;11(5):e464-e469. doi: 10.4317/jced.55698. eCollection 2019 May.

Abstract

BACKGROUND

The purpose of this study was to evaluate the deflection forces of 0.016-inch Nitinol and stainless steel orthodontic wires, in association to different self-ligating brackets.

MATERIAL AND METHODS

Specimens were mounted in a clinical simulation model and evaluated in a Universal Testing Machine (INSTRON 3342), using a 10N load cell and ISO 15,841, as a protocol. Eight of these models were prepared, each one for the bonding of each set of self-ligating accessories to be tested: Damon Q, Damon Clear (Ormco), In-Ovation R, In-Ovation C (GAC), BioQuick, QuickClear (Forestadent), SmartClip and Clarity SL (3M). Data were subjected to One-way ANOVA, followed by Tukey tests (<0.05).

RESULTS

Elastic deflection results showed that the deactivation forces increased with increase in wire deflection in the different brackets evaluated. For the different combinations, Clarity SL generated the greatest force and Damon Clear presented the lowest force when compared to the other brackets in all alloys and deflections. BioQuick and QuicKlear were those with the most similar behavior with each other.

CONCLUSIONS

Strength values increased with gradual increase in wire deflection in all evaluated brackets. Clarity SL generated the greatest and Damon Clear the lowest force when compared to the other brackets in all alloys and deflections tested. Brackets, orthodontic wires, deflection.

摘要

背景

本研究旨在评估0.016英寸镍钛合金和不锈钢正畸丝与不同自锁托槽相关的挠曲力。

材料与方法

将标本安装在临床模拟模型中,并在万能试验机(INSTRON 3342)上进行评估,使用10N的测力传感器并遵循ISO 15841标准。制备了8个这样的模型,每个模型用于将每组待测试的自锁附件进行粘接:Damon Q、Damon Clear(奥美科)、In-Ovation R、In-Ovation C(GAC)、BioQuick、QuickClear(Forestadent)、SmartClip和Clarity SL(3M)。数据进行单向方差分析,随后进行Tukey检验(<0.05)。

结果

弹性挠曲结果表明,在评估的不同托槽中,随着丝的挠曲增加,去激活力也增加。对于不同的组合,在所有合金和挠曲情况下,与其他托槽相比,Clarity SL产生的力最大,Damon Clear产生的力最小。BioQuick和QuickClear的行为彼此最为相似。

结论

在所有评估的托槽中,强度值随着丝挠曲的逐渐增加而增加。在所有测试的合金和挠曲情况下,与其他托槽相比,Clarity SL产生的力最大,Damon Clear产生的力最小。托槽;正畸丝;挠曲。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/4193/6599703/4d6777cea45a/jced-11-e464-g001.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验