Department of Systems Engineering and Automatic, Miguel Hernández University, 03202 Elche, Spain.
MovilFrio S.L., 03006 Alicante, Spain.
Sensors (Basel). 2019 Aug 2;19(15):3391. doi: 10.3390/s19153391.
In this paper, the analysis of the intensity of muscle activations in different subjects when they perform an industrial task in a repetitive way assisted by a robotic upper-limb exoskeleton is presented. To do that, surface electromyography (EMG) signals were monitored with and without a robotic upper-limb exoskeleton for 10 subjects during a drilling task, a typical tedious maintenance or industrial task. Our results show that wearing the upper-limb exoskeleton substantially reduces muscle activity during a drilling task above head height. Specifically, there is statistically significant differences in the pectoralis major and rhomboids muscles between the groups wearing or not wearing the robotic upper-limb exoskeleton.
本文分析了在重复性工业任务中,10 名受试者在使用和不使用机器人上肢外骨骼辅助时肌肉激活的强度。在这项钻孔任务中,使用表面肌电图(EMG)监测了 10 名受试者在典型的乏味维护或工业任务中的信号。结果表明,在高于头部高度的钻孔任务中,佩戴上肢外骨骼可显著降低肌肉活动。具体来说,在佩戴和不佩戴机器人上肢外骨骼的两组之间,胸大肌和菱形肌的肌肉活动存在显著的统计学差异。