Gezahegn Teshome, Tegegne Bisratewongel, Zewge Feleke, Chandravanshi Bhagwan Singh
1Department of Chemistry, College of Natural Sciences, Addis Ababa University, P.O. Box 1176, Addis Ababa, Ethiopia.
2Departement of Chemistry, College of Natural Sciences, Bahir Dar University, P.O. Box 79, Bahir Dar, Ethiopia.
BMC Chem. 2019 Mar 9;13(1):28. doi: 10.1186/s13065-019-0543-5. eCollection 2019 Dec.
The occurrence of emerging pollutants like pharmaceuticals and related compounds in the aquatic and terrestrial environments is of increasing concern. Ciprofloxacin is one of the pharmaceuticals which is active against a wide range of bacteria. The main objective of this research is to develop a simple method for the extraction and determination of ciprofloxacin residues in environmental water samples.
A salting-out assisted liquid-liquid extraction (SALLE) method for the determination of ciprofloxacin in water samples by high-performance liquid chromatography with diode array detector (HPLC-DAD) was developed. The calibration curve was linear over the range of 0.1-100 μg/L with coefficient of determination (r) of 0.9976. The limits of detection (LOD) and quantification (LOQ) of the method were 0.075 and 0.25 µg/L, respectively. The reproducibility in terms of relative standard deviation (% RSD) was less than 10%. The applicability of the developed method was investigated by analyzing tap water, bottled mineral water and waste water and demonstrated satisfactory recoveries in the ranges of 86.4-120%.
The method offered a number of features including wide linear range, good recovery, short analysis time, simple operation process and environmental friendly. The developed method can be utilized as an attractive alternative for the determination of ciprofloxacin residues in environmental water matrices.
药物及相关化合物等新兴污染物在水生和陆地环境中的出现日益受到关注。环丙沙星是一种对多种细菌有效的药物。本研究的主要目的是开发一种简单的方法来提取和测定环境水样中环丙沙星残留量。
建立了一种盐析辅助液液萃取(SALLE)法,结合二极管阵列检测器高效液相色谱(HPLC-DAD)测定水样中的环丙沙星。校准曲线在0.1 - 100μg/L范围内呈线性,决定系数(r)为0.9976。该方法的检测限(LOD)和定量限(LOQ)分别为0.075和0.25μg/L。以相对标准偏差(%RSD)表示的重现性小于10%。通过分析自来水、瓶装矿泉水和废水研究了所开发方法的适用性,回收率在86.4 - 120%范围内,结果令人满意。
该方法具有线性范围宽、回收率高、分析时间短、操作过程简单且环保等特点。所开发的方法可作为测定环境水样中环丙沙星残留量的一种有吸引力的替代方法。