Kim Bo Hee, Hyon Joon Young, Kim Mee Kum
Department of Ophthalmology, Seoul National University College of Medicine, Seoul, Korea.
Department of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Korea.
Korean J Ophthalmol. 2019 Aug;33(4):333-342. doi: 10.3341/kjo.2019.0001.
To compare the effects of bifocal versus trifocal diffractive intraocular lens (IOL) implantation on visual quality after phacoemulsification in patients with cataracts.
Eighty-eight eyes from 63 patients were analyzed. Trifocal (AT LISA tri 839MP), bifocal (AcrySof IQ ReSTOR) and bifocal (Tecnis MF ZLB00) IOLs were implanted into 53, 18, and 17 eyes, respectively. Uncorrected distance, intermediate and near visual acuity, refractive errors, contrast sensitivity, and patient satisfaction were measured at 1 week and 1 month after surgery. Refractive error was converted to a spherical equivalent and compared to predicted refraction calculated by IOL calculation formulas.
Uncorrected distance, intermediate, and near visual acuity did not differ significantly between groups. One month after surgery, the mean refractive errors were -0.07 diopters (D) in the AT LISA tri 839MP group, +0.18 D in the AcrySof IQ ReSTOR group, and +0.31 D in the Tecnis MF ZLB00 group ( < 0.001). The predictive accuracy of IOL calculation formulas did not differ between groups. Contrast sensitivity, satisfaction, and spectacle independence in the trifocal group were comparable with those of the two bifocal groups.
Trifocal IOL and two different types of bifocal IOL implantation were all effective for improving visual quality, although refractive error in patients with trifocal IOL shows myopic tendencies.
比较双焦点与三焦点衍射型人工晶状体(IOL)植入对白内障患者超声乳化术后视觉质量的影响。
分析了63例患者的88只眼。分别将三焦点(AT LISA tri 839MP)、双焦点(AcrySof IQ ReSTOR)和双焦点(Tecnis MF ZLB00)人工晶状体植入53只眼、18只眼和17只眼中。在术后1周和1个月时测量未矫正的远、中、近视力、屈光不正、对比敏感度和患者满意度。将屈光不正转换为等效球镜度,并与通过人工晶状体计算公式计算出的预测屈光度进行比较。
各组间未矫正的远、中、近视力无显著差异。术后1个月,AT LISA tri 839MP组的平均屈光不正为-0.07屈光度(D),AcrySof IQ ReSTOR组为+0.18 D,Tecnis MF ZLB00组为+0.31 D(<0.001)。人工晶状体计算公式的预测准确性在各组间无差异。三焦点组的对比敏感度、满意度和脱镜率与两个双焦点组相当。
三焦点人工晶状体和两种不同类型的双焦点人工晶状体植入均能有效改善视觉质量,尽管植入三焦点人工晶状体的患者屈光不正呈近视倾向。