Suppr超能文献

大鼠代谢率的测量:技术比较

Measurements of metabolic rate in rats: a comparison of techniques.

作者信息

Musch T I, Bruno A, Bradford G E, Vayonis A, Moore R L

机构信息

Department of Medicine, Milton S. Hershey Medical Center, Pennsylvania State University, Hershey 17033.

出版信息

J Appl Physiol (1985). 1988 Aug;65(2):964-70. doi: 10.1152/jappl.1988.65.2.964.

Abstract

Two different open-circuit techniques of measuring metabolic rate were examined in rats at rest and during exercise. With one technique ambient air was drawn through a tightly fitting mask that was secured to the rat's head, whereas with the other technique the rat was placed into and ambient air was drawn through a Plexiglas box. Two series of experiments were performed. In series I, two groups were studied that consisted of rats that had received myocardial infarctions produced by coronary arterial ligations and rats that had received sham operations. In this series of experiments O2 uptake (VO2) and CO2 production (VCO2) were measured at rest, during four levels of submaximal exercise, and during maximal treadmill exercise in the same group of rats by use of both techniques in random order. VO2, VCO2, and the calculated respiratory exchange ratio (R) were similar at rest, during the highest level of submaximal exercise (20% grade, 37 m/min), and during maximal exercise; however, VO2 and VCO2 were significantly lower with the metabolic box technique compared with the mask technique during the three lowest work loads (5% grade, 19 m/min; 10% grade, 24 m/min; and 15% grade, 31 m/min). These differences appeared to be associated with a change in gait produced when the mask was worn. In series II, the arterial blood gas and acid-base responses to both submaximal and maximal exercise were measured using both techniques in a group of instrumented rats that had a catheter placed into the right carotid artery.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

在休息和运动状态下的大鼠中,研究了两种不同的测量代谢率的开路技术。一种技术是让环境空气通过紧密贴合在大鼠头部的面罩,而另一种技术是将大鼠放入一个有机玻璃箱中,让环境空气通过该箱子。进行了两个系列的实验。在系列I中,研究了两组大鼠,一组是接受冠状动脉结扎产生心肌梗死的大鼠,另一组是接受假手术的大鼠。在这个系列实验中,对同一组大鼠在休息时、四个次最大运动水平以及最大跑步机运动期间,随机交替使用这两种技术测量氧气摄取量(VO2)和二氧化碳产生量(VCO2)。在休息时、最高次最大运动水平(坡度20%,速度37米/分钟)和最大运动时,VO2、VCO2以及计算得出的呼吸交换率(R)相似;然而,在三个最低工作负荷(坡度5%,速度19米/分钟;坡度10%,速度24米/分钟;坡度15%,速度31米/分钟)期间,与面罩技术相比,代谢箱技术测得的VO2和VCO2显著更低。这些差异似乎与佩戴面罩时产生的步态变化有关。在系列II中,在一组通过右颈动脉插入导管的仪器化大鼠中,使用这两种技术测量了次最大和最大运动时的动脉血气和酸碱反应。(摘要截断于250字)

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验