Suppr超能文献

毛细血管与静脉脑生物标志物S100B的前瞻性比较:毛细血管样本间差异大,与静脉样本的相关性差。

Prospective comparison of capillary and venous brain biomarker S100B: capillary samples have large inter-sample variation and poor correlation with venous samples.

作者信息

Vedin Tomas, Karlsson Mathias, Edelhamre Marcus, Bergenheim Mikael, Larsson Per-Anders

机构信息

Department of Clinical Sciences, Lund University, Svartbrödragränden 3-5, 251 87, Helsingborg, Sweden.

Department of Clinical Chemistry and Center for Clinical Research, Centralsjukhuset, Karlstad, Sweden.

出版信息

Int J Emerg Med. 2019 Sep 2;12(1):26. doi: 10.1186/s12245-019-0239-6.

Abstract

BACKGROUND

Guidelines for the emergency management of mild traumatic brain injury have been used for over a decade and are considered safe. However, they recommend computerized tomography for at least half of these patients. The Scandinavian Neurotrauma Committee guideline uses serum S100B protein level to rule out intracranial hemorrhage. Analysis of capillary serum S100B protein level has not yet been employed for this purpose. The primary aim of this study was to investigate the correlation and agreement of capillary and venous serum S100B protein level over a spectrum of concentrations typical for mild traumatic brain injury.

METHODS

Eighteen patients with traumatic intracranial hemorrhage and 39 volunteers without trauma to the head within the past 7 days were recruited. Blood was sampled from patients with intracranial hemorrhage daily up to four consecutive days and healthy volunteers were sampled once during the study. One venous and two capillary samples were drawn at each sampling event. Samples were analyzed using the Cobas e411 S100 electrochemiluminescence assay.

RESULTS

Median serum S100B protein level of capillary sampling 1 was 0.12 (IQR 0.075-0.21) μg/l and median serum S100B protein level of capillary sampling 2 was 0.13 (IQR 0.08-0.22) μg/l. Median serum S100B protein level of all venous samples was 0.05 (IQR 0.03-0.07) μg/l. Correlation plots of capillary and venous samples showed poor correlation and Bland-Altman plots showed a large dispersion of samples and wide limits of agreement.

CONCLUSION

The results of this study indicate that correlation and agreement between capillary and venous samples are low, and because of this, we cannot recommend studies on capillary serum S100B protein level to rule out intracranial hemorrhage in mild traumatic brain injury. Given the limitations of the current sampling and analysis methods of capillary protein S100B protein level, we conclude that evaluating its predictive ability to rule out intracranial hemorrhage should be withheld until more reliable methods can be incorporated into the study design.

摘要

背景

轻度创伤性脑损伤的应急管理指南已使用了十多年,且被认为是安全的。然而,这些指南建议至少对一半的此类患者进行计算机断层扫描。斯堪的纳维亚神经创伤委员会指南使用血清S100B蛋白水平来排除颅内出血。尚未将毛细血管血清S100B蛋白水平分析用于此目的。本研究的主要目的是调查在轻度创伤性脑损伤典型的一系列浓度范围内,毛细血管和静脉血清S100B蛋白水平的相关性和一致性。

方法

招募了18例创伤性颅内出血患者和39名在过去7天内无头部创伤的志愿者。对颅内出血患者连续4天每天采血,健康志愿者在研究期间采血一次。每次采样时采集一份静脉血样和两份毛细血管血样。使用Cobas e411 S100电化学发光分析法对样本进行分析。

结果

毛细血管采样1的血清S100B蛋白水平中位数为0.12(四分位间距0.075 - 0.21)μg/l,毛细血管采样2的血清S100B蛋白水平中位数为0.13(四分位间距0.08 - 0.22)μg/l。所有静脉血样的血清S100B蛋白水平中位数为0.05(四分位间距0.03 - 0.07)μg/l。毛细血管和静脉血样的相关性图显示相关性较差,布兰德-奥特曼图显示样本离散度大且一致性界限宽。

结论

本研究结果表明,毛细血管和静脉血样之间的相关性和一致性较低,因此,我们不建议通过研究毛细血管血清S100B蛋白水平来排除轻度创伤性脑损伤中的颅内出血。鉴于目前毛细血管蛋白S100B蛋白水平采样和分析方法的局限性,我们得出结论,在将更可靠的方法纳入研究设计之前,应暂停评估其排除颅内出血的预测能力。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/67b3/6719369/b0b81f763ba2/12245_2019_239_Fig1_HTML.jpg

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验