Department of Ophthalmology, Chungnam National University College of Medicine, Daejeon, Korea.
Department of Ophthalmology, Konyang University College of Medicine, Daejeon, Korea.
Acta Ophthalmol. 2020 Feb;98(1):e36-e42. doi: 10.1111/aos.14203. Epub 2019 Sep 11.
To determine the long-term repeatability of optical coherence tomography angiography (OCTA) parameters in normal eyes.
We prospectively enrolled 104 normal eyes. Participants were divided into three groups based on differences in the signal strength (SS) of OCTA scans obtained at two visits at least 6 months apart: group 1, SS difference = 2; group 2, 1; group 3, 0. We measured a foveal centred scan area of 3 × 3 mm pattern. All measurements were performed twice at 5-min intervals at the initial visit. The second measurements were performed at least 6 months later.
In short-term vessel density (VD) repeatability, the coefficient of variation (CV) ranged from 3.89% to 8.10% and the intraclass correlation coefficient (ICC) ranged from 0.785 to 0.941. In terms of long-term repeatability, the CV was 5.39-12.62% and the ICC was 0.598-0.867. In group 1, the ICCs of the inner and full VDs were 0.194 and 0.221, respectively. In groups 2 and 3, the ICCs of the inner and full VDs were 0.611 and 0.603, and 0.763 and 0.765, respectively. The central VDs of all groups had high CV besides high ICC.
Optical coherence tomography angiography parameters showed good short-term and reasonable long-term repeatability in normal individuals. The differences in SSs between measurements affected such repeatability, so physicians should query the reliability of OCTA parameters when the differences in SS are 2 or more even when the SS is high.
确定正常眼的光相干断层扫描血管造影(OCTA)参数的长期可重复性。
我们前瞻性地招募了 104 只正常眼。根据两次访视获得的 OCTA 扫描信号强度(SS)差异,将参与者分为三组:组 1,SS 差异=2;组 2,1;组 3,0。我们测量了一个以黄斑为中心的 3×3mm 扫描区域。所有测量均在初始访视时相隔 5 分钟进行两次。第二次测量至少在 6 个月后进行。
在短期血管密度(VD)重复性方面,变异系数(CV)范围为 3.89%至 8.10%,组内相关系数(ICC)范围为 0.785 至 0.941。就长期重复性而言,CV 为 5.39%-12.62%,ICC 为 0.598-0.867。在组 1 中,内和全 VD 的 ICC 分别为 0.194 和 0.221。在组 2 和 3 中,内和全 VD 的 ICC 分别为 0.611 和 0.603,0.763 和 0.765。所有组的中央 VD 除了高 ICC 外,CV 也很高。
在正常个体中,OCTA 参数具有良好的短期和合理的长期重复性。测量之间 SS 的差异会影响这种可重复性,因此,即使 SS 较高,当 SS 差异为 2 或更多时,医生也应该查询 OCTA 参数的可靠性。