Peraza-Nieves Jorge, Sánchez-González José-María, Rocha-de-Lossada Carlos, Rachwani-Anil Rahul, Sánchez-Valera Miriam, Borroni Davide, Torras-Sanvicens Josep
Department of Ophthalmology, Hospital Clinic de Barcelona Institut Clinic D'Oftalmologia, Barcelona, Spain.
Department of Physics of Condensed Matter, Optics Area, University of Seville, Reina Mercedes Street, Seville, Spain.
Int Ophthalmol. 2023 Dec;43(12):4409-4417. doi: 10.1007/s10792-021-01817-x. Epub 2021 Mar 24.
To compare corneal densitometry in a consecutive series of 52 endothelial keratoplasties (DMEK/DSAEK) using a Scheimpflug-based device after six months of follow-up.
Corneal densitometry (CD) values of 102 eyes were divided into three main groups: 33 DMEKs, 19 DSAEKs, and 50 healthy eyes without previous ocular surgery. The CD values were then analyzed and compared between the groups. We measured three main layers in depth and four different concentric zones at 1, 3, and 6 months postoperatively.
In the DMEK group, total CD significantly decreased from 38.02 ± 10.21 grayscale units (GSU) to 31.13 ± 9.25 GSU (P < 0.01) between the first and the sixth month postoperative. In the DSAEK group, we found significant changes only between the first and three months after surgery (from 42.62 ± 9.31 GSU to 38.71 ± 10.53 GSU (P < 0.01). Regarding the concentric zones, CD in the DMEK group significantly decreased in the central zone from 33.55 ± 12.07 GSU to 30.63 ± 10.15 GSU (P < 0.01) and significantly increased in the periphery from 30.63 ± 10.15 GSU to 36.72 ± 9.37 GSU, (P < 0.01). The DSAEK group showed no changes in the central zone (from 36.91 ± 13.80 GSU to 36.14 ± 11.47 GSU, P = 0.52) and CD significantly increased in the periphery (41.91 ± 9.28 GSU, P < 0.01).
When comparing CD values in DMEK versus DSAEK, we found no differences by layers or at central-paracentral concentric zones, although CD differences in the peripheral zones were statistically significant. This finding may be attributed to the thicker graft at periphery with a delayed clearance and less anatomical interphase in DSAEK.
使用基于Scheimpflug原理的设备,对连续52例接受内皮角膜移植术(DMEK/DSAEK)的患者进行随访6个月后的角膜密度测量进行比较。
102只眼的角膜密度测量(CD)值分为三个主要组:33只接受DMEK手术的眼睛、19只接受DSAEK手术的眼睛和50只未接受过眼部手术的健康眼睛。然后对各组之间的CD值进行分析和比较。我们在术后1、3和6个月测量了三个主要深度层和四个不同的同心区域。
在DMEK组中,术后第一个月至第六个月期间,总CD值从38.02±10.21灰度单位(GSU)显著降至31.13±9.25 GSU(P<0.01)。在DSAEK组中,仅在术后第一个月至第三个月之间发现了显著变化(从42.62±9.31 GSU降至38.71±10.53 GSU,P<0.01)。关于同心区域,DMEK组中央区域的CD值从33.55±12.07 GSU显著降至30.63±10.15 GSU(P<0.01),周边区域从30.63±10.15 GSU显著增至36.72±9.37 GSU(P<0.01)。DSAEK组中央区域无变化(从36.91±13.80 GSU降至36.14±11.47 GSU,P=0.52),周边区域的CD值显著增加(41.91±9.28 GSU,P<0.01)。
比较DMEK和DSAEK的CD值时,我们发现各层或中央-旁中央同心区域无差异,尽管周边区域的CD差异具有统计学意义。这一发现可能归因于DSAEK周边移植片较厚,清除延迟且解剖界面较少。