PurposeThe aim of this study was to gain greater insight into the corneal densitometry changes occurring as a result of refractive surgery and to compare these changes across three widely used surgical techniques, namely, photorefractive keratectomy (PRK), laser-assisted in situ keratomileusis with a femtosecond laser (LASIK-FS), or ReLEx small-incision lenticule extraction (ReLEx SMILE).Patients and methodsThree hundred and thirty-six patients (184 male and 152 female patients) participated in this study. They were split into three groups according to the refractive surgery technique they had undergone: LASIK-FS (74 patients), PRK (153 patients), and ReLEx SMILE (109 patients). All participants underwent an exhaustive eye examination both before and after surgery. Pre- and postoperative corneal densitometry was measured using an Oculus Pentacam system.ResultsThe mean postoperative total corneal densitometry values were 16.53±1.94 for the LASIK-FS group, 15.53±1.65 for PRK, and 16.10±1.54 for ReLEx SMILE. When corneal densitometry was analyzed for specific corneal areas, the values corresponding to the 0-2, 2-6, and 6-10 mm annuli were similar across the three surgical techniques. The only region in which differences were found was the peripheral area (P<0.05), but these variations across techniques were not statistically significant.ConclusionsCorneal densitometry can be used as an objective metric to assess corneal response to refractive surgery, and to monitor patients over time. Corneal densitometry was not negatively affected by any of the refractive surgical procedures under evaluation.

摘要

目的

本研究的目的是更深入地了解屈光手术导致的角膜密度测量变化,并比较三种广泛使用的手术技术,即准分子激光原位角膜磨镶术(PRK)、飞秒激光制瓣准分子原位角膜磨镶术(LASIK-FS)或全飞秒激光微小切口基质透镜切除术(ReLEx SMILE)之间的这些变化。

患者与方法

336名患者(184名男性和152名女性患者)参与了本研究。他们根据所接受的屈光手术技术分为三组:LASIK-FS组(74例患者)、PRK组(153例患者)和ReLEx SMILE组(109例患者)。所有参与者在手术前后均接受了全面的眼部检查。使用Oculus Pentacam系统测量术前和术后的角膜密度。

结果

LASIK-FS组术后角膜总密度测量值的平均值为16.53±1.94,PRK组为15.53±1.65,ReLEx SMILE组为16.10±1.54。当分析特定角膜区域的角膜密度时,三种手术技术在0-2、2-6和6-10毫米环形区域对应的数值相似。唯一发现差异的区域是周边区域(P<0.05),但这些技术间的差异无统计学意义。

结论

角膜密度测量可作为评估角膜对屈光手术反应以及长期监测患者的客观指标。角膜密度测量未受到所评估的任何屈光手术的负面影响。

相似文献

引用本文的文献

本文引用的文献

3
Changes in straylight and densitometry values after corneal collagen crosslinking.角膜胶原交联术后杂散光和密度测量值的变化。
J Cataract Refract Surg. 2015 May;41(5):1038-43. doi: 10.1016/j.jcrs.2014.07.043. Epub 2015 May 5.
5
Corneal densitometry in keratoconus.圆锥角膜的角膜密度测量法
Cornea. 2014 Dec;33(12):1282-6. doi: 10.1097/ICO.0000000000000266.
8
In vivo characterization of corneal biomechanics.角膜生物力学的体内特征分析。
J Cataract Refract Surg. 2014 Jun;40(6):870-87. doi: 10.1016/j.jcrs.2014.03.021.