Suppr超能文献

汞合金替代品的批判性评估:长期热机械加载对边缘质量、磨损和断裂行为的影响。

Amalgam Alternatives Critically Evaluated: Effect of Long-term Thermomechanical Loading on Marginal Quality, Wear, and Fracture Behavior.

出版信息

J Adhes Dent. 2020;22(1):107-116. doi: 10.3290/j.jad.a44001.

Abstract

PURPOSE

This in vitro study evaluated marginal integrity, 2-body wear, and fracture behavior of an array of bonded and nonbonded posterior restorative materials after thermomechanical loading (TML).

MATERIALS AND METHODS

Eighty-eight MOD cavities with one proximal box beneath the CEJ were prepared in extracted human third molars according to a well-established protocol. Direct restorations were made using the following materials: amalgam (Dispersalloy), Ketac Molar Quick, Surefil One (with or without light curing), Activa, AdheSE Universal/Heliomolar, Fuji II LC improved, Equia Forte, Scotchbond Universal/Filtek Supreme, Xeno V+/CeramX.mono+, Prime&Bond active/Spectra ST CeramX HV, Prime&Bond elect/Spectra ST CeramX HV. Before and after thermomechanical loading (2500/5000/12,500 thermocycles between 5°C and 55°C + 100,000/ 200,000/500,000 x 50 N), marginal gaps and 2-body wear depths were analyzed on epoxy resin replicas using SEM and CLSM. Fractures were observed under a light microscope (20X). Results were analyzed with Kruskal-Wallis and Mann-Whitney U-tests (p < 0.05).

RESULTS

For marginal quality, Surefil One showed promising in vitro behavior close to that of resin composite bonded with a self-etch adhesive (p > 0.05). For wear, amalgam and resin composites with recent filler technology were still superior (p < 0.05), but Surefil One LC outperformed Activa, Ketac Molar Quick, Equia Forte Fil, and Fuji II LC (p < 0.05). When Surefil One was occlusally light cured, no fractures occured, even after 500,000 cycles of TML.

CONCLUSION

The novel self-adhesive posterior restorative Surefil One did not exhibit superior outcomes for all evaluated aspects. However, it showed stable fracture behavior, good marginal quality, and acceptable wear resistance in vitro.

摘要

目的

本体外研究评估了经热机械负载(TML)后一系列粘结和非粘结后牙修复材料的边缘完整性、2 体磨损和断裂行为。

材料和方法

根据既定方案,在 88 个下颌第三磨牙的近中牙本质下制备了 88 个 MOD 腔。使用以下材料制作直接修复体:银汞合金(Dispersalloy)、Ketac Molar Quick、Surefil One(有或无光固化)、Activa、AdheSE Universal/Heliomolar、Fuji II LC improved、Equia Forte、Scotchbond Universal/Filtek Supreme、Xeno V+/CeramX.mono+、Prime&Bond active/Spectra ST CeramX HV、Prime&Bond elect/Spectra ST CeramX HV。在 TML(5°C 至 55°C 之间的 2500/5000/12500 个热循环+100000/200000/500000x50N)前后,使用 SEM 和 CLSM 在环氧树脂复制品上分析边缘间隙和 2 体磨损深度。在 20X 光显微镜下观察断裂情况。使用 Kruskal-Wallis 和 Mann-Whitney U 检验(p < 0.05)对结果进行分析。

结果

对于边缘质量,Surefil One 表现出与用自酸蚀粘结剂粘结的树脂复合材料接近的有前途的体外行为(p > 0.05)。对于磨损,具有最新填充技术的银汞合金和树脂复合材料仍具有优势(p < 0.05),但 Surefil One LC 优于 Activa、Ketac Molar Quick、Equia Forte Fil 和 Fuji II LC(p < 0.05)。当 Surefil One 牙合面光固化时,即使经过 500000 次 TML,也不会发生断裂。

结论

新型自粘结后牙修复材料 Surefil One 在所有评估方面均未表现出优异的结果。然而,它表现出稳定的断裂行为、良好的边缘质量和可接受的体外耐磨性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验