University of Detroit Mercy School of Dentistry-Graduate Endodontics, University of Detroit Mercy School of Dentistry, Detroit, Michigan.
University of Michigan School of Dentistry-MicroCT Core, Ann Arbor, Michigan.
J Endod. 2020 Feb;46(2):244-251.e1. doi: 10.1016/j.joen.2019.11.001.
This study evaluated and compared the shaping ability of the WaveOne Gold (Dentsply/Tulsa Dental Specialties, Tulsa, OK), TRUShape 3D Conforming File (Dentsply/Tulsa Dental Specialties), EdgeCoil (EdgeEndo, Albuquerque, NM), and XP-3D Shaper (Brasseler USA, Savannah, GA) endodontic file systems on oval-shaped canals using micro-computed tomographic (micro-CT) technology.
Thirty-two oval-shaped, single-canal extracted human teeth were decoronated 1 mm coronal to the cementoenamel junction and scanned via a micro-CT scanner (μCT100; Scanco Medical, Bassersdorf, Switzerland). Teeth were divided into 4 groups (n = 8) and instrumented according to the manufacturer's instructions. Coregistered images, before and after root canal preparation, were evaluated for morphometric measurements of the surface area, volume, structure model index (SMI), conicity, and percent of walls untouched using the manufacturer's evaluation software (IPL Register, Scanco Medical). Data were statistically compared between groups using 1-way analysis of variance and within groups using a paired sample t test.
Instrumentation with all file types increased the surface area, volume, and conicity between and within groups. There was no statistically significant difference between the groups for any of the rotary instruments used (P < .05).
Instrumentation of oval-shaped canals with WaveOne Gold, TRUShape, EdgeCoil, and XP-3D Shaper rotary endodontic instruments similarly increase the volume, surface area, and conicity. None of the file systems were capable of contacting all of the surface area in any canal.
本研究采用 micro-CT 技术评估和比较了 WaveOne Gold(登士柏/图尔萨牙科专业公司,塔尔萨,俄克拉荷马州)、TRUShape 3D 顺应性锉(登士柏/图尔萨牙科专业公司)、EdgeCoil(EdgeEndo,阿尔伯克基,新墨西哥州)和 XP-3D Shaper(Brasseler USA,萨凡纳,佐治亚州)根管锉系统在椭圆形根管中的成形能力。
将 32 颗椭圆形、单根管的人离体牙在牙颈下 1mm 处进行去冠,并使用 micro-CT 扫描仪(μCT100;Scanco Medical,巴塞尔多夫,瑞士)进行扫描。牙齿被分为 4 组(n=8),并按照制造商的说明进行器械预备。使用制造商的评估软件(IPL Register,Scanco Medical)对预备前后的根管进行配准图像,评估表面面积、体积、结构模型指数(SMI)、锥度和未触及壁的百分比等形态学测量值。采用单因素方差分析对组间数据进行比较,采用配对样本 t 检验对组内数据进行比较。
所有类型的锉都能增加表面面积、体积和锥度,且在组间和组内都有统计学意义。使用的任何旋转器械之间在任何参数上都没有统计学差异(P<0.05)。
WaveOne Gold、TRUShape、EdgeCoil 和 XP-3D Shaper 旋转根管锉系统对椭圆形根管的预备可类似地增加体积、表面面积和锥度。在任何根管中,没有任何一种锉系统能够接触到所有的表面。