Department of Chemistry, Fudan University, Shanghai, 200438, China.
Department of Chemistry and Environmental Science, New Jersey Institute of Technology, Newark, NJ, 07102, USA.
Nat Commun. 2020 Feb 26;11(1):1049. doi: 10.1038/s41467-020-14877-x.
Enzymatic digestion for protein sequencing usually requires much time, and does not always result in high sequence coverage. Here we report the use of aqueous microdroplets to accelerate enzymatic reactions and, in particular, to improve protein sequencing. When a room temperature aqueous solution containing 10 µM myoglobin and 5 µg mL trypsin is electrosonically sprayed (-3 kV) from a homemade setup to produce tiny (∼9 µm) microdroplets, we obtain 100% sequence coverage in less than 1 ms of digestion time, in sharp contrast to 60% coverage achieved by incubating the same solution at 37 °C for 14 h followed by analysis with a commercial electrospray ionization source that produces larger (∼60 µm) droplets. We also confirm the sequence of the therapeutic antibody trastuzumab (∼148 kDa), with a sequence coverage of 100% for light chains and 85% for heavy chains, demonstrating the practical utility of microdroplets in drug development.
用于蛋白质测序的酶解通常需要很长时间,而且并不总是能得到高的序列覆盖率。在这里,我们报告了使用水微滴来加速酶反应,特别是提高蛋白质测序的效率。当含有 10μM 肌红蛋白和 5μg/mL 胰蛋白酶的室温水溶液在自制装置中进行电喷雾(-3kV)以产生微小的(约 9μm)微滴时,我们在不到 1ms 的消化时间内获得了 100%的序列覆盖率,与在 37°C 孵育相同溶液 14 小时后再用商业电喷雾电离源分析相比,后者的覆盖率仅为 60%,且电喷雾源产生的液滴更大(约 60μm)。我们还确认了治疗性抗体曲妥珠单抗(约 148kDa)的序列,轻链的序列覆盖率为 100%,重链的序列覆盖率为 85%,证明了微滴在药物开发中的实际应用。